Among patients undergoing CIED procedures, 2.33% experienced major infections within three months, with in-hospital mortality reaching 8.4% for pocket infections and 15.0% for endocarditis.
Observational (n=282,205)
Yes
Nationwide German claims data reveal that acute CIED infections occur in 2.33% of patients within 90 days, representing a higher rate than previously reported, and are associated with substantial in-hospital mortality and procedural burden.
Abstract Background Cardiovascular implantable electronic devices (CIEDs) improve survival in patients with cardiac rhythm disorders but carry risks of complications, most notably major infections. Reported infection rates vary internationally, and contemporary large-scale data from Germany are scarce. We aimed to determine nationwide rates of CIED infection-related hospitalizations and associated mortality over a five-year period. Methods We analyzed administrative claims from Germany’s largest statutory health insurer covering more than 27 million beneficiaries. All CIED procedures performed between January 2015 and December 2019 were identified, including initial implantations, upgrades or downgrades, generator replacements, early revisions, and device extractions. Major infections were detected using International Classification of Diseases (ICD-10-GM) and procedural codes, and stratified as generator pocket infections or lead-associated endocarditis. In-hospital mortality was determined from discharge records. Results Among 282,205 patients (57.7% male) undergoing CIED procedures, 6,577 individuals (2.33%) experienced 7,704 major infections within three months. Generator pocket infections occurred in 5,396 cases (1.91%), lead-associated endocarditis in 2,308 (0.82%), and combined infections in 1,127 patients (0.39%) within the acute 90-day observation period. CIED infections substantially increased healthcare utilization: Infected patients required substantially more procedures than non-infected patients, despite correct treatment. In-hospital mortality reached 8.36% for pocket infections and 15.0% for endocarditis. Extended follow-up in the 2015 cohort revealed a 4.33% infection-related procedure rate over five years. Conclusions Nationwide German data reveal higher acute CIED infection rates than previously reported, with considerable mortality and procedural burden. These findings highlight an urgent need for improved prevention and management strategies.
Baldauf et al. (Fri,) conducted a observational in Cardiac implantable electronic device (CIED) procedures (n=282,205). Cardiac implantable electronic device (CIED) procedures was evaluated on Major CIED infections requiring hospitalization within 3 months (95% CI 2.28%-2.39%). Among patients undergoing CIED procedures, 2.33% experienced major infections within three months, with in-hospital mortality reaching 8.4% for pocket infections and 15.0% for endocarditis.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: