Key result
Valve-in-valve TAVR yields similar 30-day major cardiovascular events rates compared to redoSAVR in women with degenerated bioprostheses.
Why the study?
Women with valvular disease historically have higher procedural risks than men, but outcomes of aortic valve reinterventions in women remain poorly understood.
Does Valve-in-Valve transcatheter aortic valve replacement reduce 30-day all-cause mortality, stroke, and major adverse cardiac events compared to redo-surgical aortic valve replacement in women with degenerated aortic bioprosthesis?
Cohort (n=132)
No
Does Valve-in-Valve transcatheter aortic valve replacement reduce 30-day all-cause mortality, stroke, and major adverse cardiac events compared to redo-surgical aortic valve replacement in women with degenerated aortic bioprosthesis?
Valve-in-Valve TAVR and redo surgical aortic valve replacement yield similar short-term and 1-year outcomes in women with degenerated aortic bioprostheses, suggesting both are valid treatment options.
Answers are grounded in this paper and cite their sources.
Short-term safety appears similar for ViV and redoSAVR in women; leaves open optimal strategy selection pending larger studies.
BACKGROUND: Bioprosthetic aortic valves require reinterventions once they degenerate. Options include redo-surgical aortic valve replacement (redoSAVR) and Valve-in-Valve transcatheter aortic valve replacement (ViV). Women with valvular disease have historically demonstrated higher procedural risks and worse outcomes compared to men. There is a knowledge gap regarding outcomes of aortic valve reinterventions in women. AIMS: We sought to compare outcomes of ViV versus redoSAVR in women with degenerated bioprosthetic surgical valves. METHODS: Consecutive female patients with prior SAVR undergoing isolated ViV or redoSAVR between 2015 and 2025 were included. Primary endpoints were 30-day all-cause mortality, stroke, and major adverse cardiac events (MACE). Secondary (1-year) endpoints included mortality, stroke, MACE, pacemaker implantation, and cardiac rehospitalization. Propensity score matching (PSM), Cox regression for survival, and Kaplan-Meier for MACE were performed. RESULTS: Forty redoSAVR and 92 ViV female patients were included. ViV females were older, had lower BMI, and higher STS-PROM. Primary endpoints were not significantly different between ViV and redoSAVR: mortality 1 (1.1%) versus 1 (2.5%), p = 0.303; stroke 3 (3.3%) versus 2 (5.0%), p = 0.480; MACE 3 (3.3%) versus 3 (7.5%), p = 0.272. 1-year endpoints were also comparable: mortality 8 (8.7%) versus 3 (7.5%), p = 0.867; stroke 4 (4.3%) versus 2 (5.0%), p = 0.834; MACE 11 (12.0%) versus 5 (12.5%), p = 0.888; pacemaker 3 (3.3%) versus 1 (2.5%), p = 0.792; rehospitalization 10 (10.9%) versus 2 (5.0%), p = 0.265). Results were consistent before and after PSM. CONCLUSIONS: ViV and redoSAVR in women yielded similar short-term outcomes. Both represent valid options for treatment of degenerated aortic bioprosthesis.
No takes yet. Share an insight, caveat, or question.
Tagliafierro et al. (2026) conducted a cohort in Degenerated aortic bioprosthesis (n=132). Valve-in-Valve transcatheter aortic valve replacement (ViV) vs. redo-surgical aortic valve replacement (redoSAVR) was evaluated on 30-day major adverse cardiac events (MACE) (p=0.272). Valve-in-Valve TAVR yielded similar 30-day rates of major adverse cardiac events compared to redoSAVR in women with degenerated aortic bioprostheses.
Synapse has enriched 10 related papers. Consider them for comparative context: