Demonstrates real-time temperature and humidity monitoring in concrete, highlighting its role in preventing defects.
Concrete structures require precise temperature and humidity monitoring during curing to ensure optimal strength and to prevent defects such as cracking. A compact optical sensing system was developed using a single fiber that can be embedded directly within the concrete. When paired with a spectral interrogation unit operating in the low-loss single-mode communications band of 1500–1600 nm, the system functions as both a temperature and relative humidity (RH) sensor. Temperature monitoring is achieved using a Fiber Bragg Grating, while humidity sensing is provided by a Fabry-Perot interferometer (FPI) at the fiber tip. The interferometer cavity is formed with a layer of polyvinylpyrrolidone (PVP), an RH-sensitive polymer. The system exhibited a response time of approximately 3 h and operated over a relative humidity range of 50–95% RH and a temperature range of 30–60 ∘ C, with normalized free spectral range sensitivities of the FPI up to 35 m − 1 /%RH at high humidity levels. The system was validated using a small-scale 50-day in-concrete test.
No takes yet. Share an insight, caveat, or question.
Faria et al. (2026) studied this question.