This is the authors' abstract. We don't add key points for this paper.
This study presents a fiber-optic Fabry-Perot humidity sensor based on a concave-etched graded-index (GRIN) fiber and a thin composite hydrogel diaphragm. The concave cavity is made using chemical acid etching and a thin layer of chitosan-tetraethyl orthosilicate (Chi:TEOS) hydrogel. The hydrogel is placed inside the cavity using capillary forces to form a Fabry-Perot interferometer. The swelling behavior of the hydrogel in response to humidity variations leads to changes in the cavity length, resulting in a wavelength shift of the interference spectrum. Additionally, the hydrogel film is covalently bonded to the fiber surface through air plasma treatment, ensuring structural stability and reliable integration. The sensor demonstrated a sensitivity of 1.4 pm/%RH in the range from 20% to 62% RH. Additionally, the interference spectrum showed responses to temperature changes, with a measured temperature sensitivity of approximately 38.2 pm/°C. Fourier domain analysis also demonstrated a dual-parameter sensing capability, allowing for the simultaneous estimation of temperature and humidity from spectral features. It exhibited a robust architecture suitable for harsh environments due to the protective nature of the embedded fiber structure. This design introduces a mechanically resilient and optically responsive platform for compact humidity sensing applications.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Moghaddam et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: