Key result
Echocardiographic measurements of ventricular wall thickness in cats differed by less than 15% from postmortem and cineangiographic measurements, with an average deviation of -0.01 +/- 0.26 mm.
Population
33 normal healthy domestic cats, including 12 males and 13 females in the reference group, weighing between…
Comparison
Echocardiographic examination vs Cineangiography and postmortem measurements
Design
Preclinical
Authors
Loading...
Confirms echocardiographic validity for feline ventricular measurements; leaves open extension to clinical disease states.
Observational (n=33)
This study establishes normal echocardiographic reference values for domestic cats and validates them against cineangiographic and postmortem measurements.
Pipers et al. (1979) conducted an observational in Normal healthy cats (n=33). Echocardiography vs. Postmortem and cineangiographic measurements was evaluated on Echocardiographic reference values and deviation from postmortem measurements. Echocardiographic measurements of ventricular wall thickness in cats differed by less than 15% from postmortem and cineangiographic measurements, with an average deviation of -0.01 +/- 0.26 mm.