Key result
Contrast-enhanced echocardiography yields ~0.6-mm thinner feline LV wall measurements than standard echocardiography.
Why the study?
Accurate measurement of feline left ventricular wall thickness is challenging due to anatomical irregularities, and the comparative performance of contrast-enhanced versus standard echocardiography in cats was unknown.
Does contrast-enhanced echocardiography improve the reliability, repeatability, and reproducibility of left ventricular wall thickness measurements compared to standard echocardiography in cats?
Cross-Sectional (n=50)
Does contrast-enhanced echocardiography improve the reliability, repeatability, and reproducibility of left ventricular wall thickness measurements compared to standard echocardiography in cats?
Contrast-enhanced echocardiography is a feasible method in cats that provides superior repeatability, reproducibility, and reliability for measuring left ventricular wall thickness compared to standard echocardiography.
May improve feline LVWT precision; leaves open whether it alters HCM diagnosis or outcomes.
Introduction/Objectives Accurate measurement of feline left ventricular (LV) wall thickness is challenging due to endocardial and myocardial irregularities, false tendons, and prominent papillary muscles. In human medicine, contrast-enhanced echocardiography (C-Echo) is used to improve LV wall delineation and is more accurate, repeatable, and reliable than standard echocardiography (S-Echo). Our objective was to compare C-Echo and S-echo measurements of feline LV wall thickness (LVWT) and determine repeatability, reproducibility, and reliability of each modality. Animals Fifty client-owned cats were prospectively enrolled. Materials and Methods Cats underwent S-Echo and C-Echo after intravenous injection of contrast agent. Methods were compared using Bland-Altman and Passing-Bablok regression. Inter- and intra-operator reproducibility, repeatability, and reliability were quantified using intraclass correlation (ICC), repeatability coefficients (RC), and coefficients of variation (CV). Results Standard echocardiography and C-Echo differed significantly for all segments with a median difference of 0.56 mm (range: –1.4 to 4.9 mm; P < 0.0001). Regression showed proportional bias (slope 1.21, CI 1.11–1.31) with minimal systematic bias (intercept –0.26, CI –0.64 to 0.12). Intra- and inter-operator reproducibility was excellent for both modalities (ICC 0.90–0.94 for S-Echo; 0.86–0.99 for C-Echo), while RCs were lower for C-Echo (0.28–0.61 mm) than S-Echo (0.89–1.03 mm), and CVs were lower for C-Echo (intra-observer 5.86%, inter-observer 3.03%) than S-Echo (7.43% and 7.64%). Limitations Accuracy of S-Echo and C-Echo compared with a reference standard not assessed. Conclusions Contrast-enhanced echocardiography is feasible and provides excellent LV wall visualization with lower LVWT measurements and superior repeatability, reproducibility, and reliability.
No takes yet. Share an insight, caveat, or question.
Javery et al. (2026) conducted a cross-sectional in Feline left ventricular wall thickness (n=50). Contrast-enhanced echocardiography vs. Standard echocardiography was evaluated on Measurement of left ventricular wall thickness (Median difference 0.56 mm, p=<0.0001). Contrast-enhanced echocardiography yielded significantly lower feline left ventricular wall thickness measurements than standard echocardiography (median difference 0.56 mm; P<0.0001).