Randomized trial explores shear capacity in assembled composite walls, suggesting design improvements for seismic resistance.
To investigate the influence of dry connection methods on the seismic behavior of assembled composite walls, four assembled composite walls were designed and tested. Various dry connection techniques were adopted for the horizontal interfaces, namely sleeve grouting connection, welding connection, box connection, and bolted connection. The failure process, failure mode, bearing capacity, rigidity, steel bar strain, and energy absorption performance of the specimens were investigated through quasi-static cyclic loading tests. The results indicate that all types of connectors can effectively transfer loads and satisfy the conceptual design principle of “strong joint and weak component”. The damage evolution of the specimens is essentially identical, and the limiting drift angles all exceed 1/90. In addition, the shear resistance of the specimens with different connection methods is preliminarily analyzed and estimated.