Demonstrates improved voltage regulation in single-phase PWM rectifiers, indicating better power quality.
In single-phase PWM rectifiers, due to the inherent time-varying characteristics of the source voltage and current as well as the periodic operation of the converter bridge, the instantaneous input power on the AC side inevitably exhibits a twice-fundamental-frequency pulsation. This phenomenon consequently generates a double-line-frequency (100 Hz) voltage ripple on the DC-link capacitor, which causes an inherent contradiction in conventional voltage outer-loop control between steady-state ripple suppression and dynamic response speed. To address this issue, this paper proposes a control strategy based on an Adaptive Time-Delayed Feedforward Neural Network (Adaptive TD-FNN). The proposed method explicitly introduces the delayed voltage error of half a ripple period into the network state input, thereby achieving time-domain decoupling of the 100 Hz low-frequency disturbance. In addition, a physics-driven training framework is constructed by integrating the rectifier’s discrete difference equation, thereby strengthening the network’s capacity to learn the dynamic characteristics of the system. On this basis, a dynamic adaptive smoothness-weight penalty mechanism is designed to adjust the weighting factor of the current command smoothness constraint in the loss function according to the system operating state. Specifically, the penalty weight is increased under steady-state conditions to suppress command oscillations caused by ripple disturbances, while it is rapidly reduced during load or grid-voltage transients to release the network’s transient optimization capability. Simulation and experimental results show that the proposed Adaptive TD-FNN controller can simultaneously achieve smooth steady-state current command output and fast dynamic voltage regulation without introducing additional complex digital notch-filtering algorithms. Compared with conventional dual-loop control, the proposed strategy reduces the total harmonic distortion (THD) of the grid-side input current from 8.45% to 3.42%, satisfying grid-connected power quality requirements. Meanwhile, under large load transients and grid-voltage disturbance conditions, the DC-link voltage recovery time is about 40 ms, verifying the comprehensive advantages of the proposed method in ripple suppression, dynamic response, and operating-condition adaptability.
No takes yet. Share an insight, caveat, or question.
He et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: