Evaluates lesion detection and quantification in prostate cancer, suggesting improved diagnostic capabilities.
Purpose The aim of this study was to investigate the limits of diagnostics and therapy planning for patients with prostate cancer using non-time-of-flight 18 F/ 68 Ga-PSMA PET/MRI under clinically challenging imaging conditions with small lesion sizes and low uptake. Lesion detectability and quantification accuracy were evaluated for different acquisition and reconstruction parameters in a systematic phantom study and subsequent on patient data. Methods PET/MRI measurements were performed using a small lesion NEMA phantom. PET data were acquired for nine different activity concentrations (AC). Data of a longer single-bed protocol in the pelvis or a shorter whole-body protocol were reconstructed using relative or absolute scatter correction (SC). PET images were analysed considering a ± 25% deviation range between imaged and true AC as acceptable. Thirteen PSMA-PET/MRI patients with primary lesions or lymph node metastasis < 12 mm in the pelvis were included in this study. The presence of the halo artefact was evaluated in six 18 F-PSMA and seven 68 Ga-PSMA PET/MRI patients. For 21 lesions (diameter 6.4–12.3 mm) in total, the AC was quantified. Results For both radiotracers, the 9.7 mm sphere was still visible at 0.16 kBq/mL with emission times > 40 min. The 3.7 mm sphere was only detectable at 22 kBq/mL with emission times > 4 min. All spheres ≥ 6.5 mm provide acceptable quantification at an AC of 1.32 kBq/mL for 18 F PET/MRI protocols of ≥ 12 min and 2.75 kBq/mL for 68 Ga PET/MRI protocols. In phantom data, no halo artefact was observable and different SC methods had no impact on quantification. 4/6 18 F-PSMA patients and 7/7 68 Ga-PSMA patients showed a halo around the bladder using relative SC, which could be reduced in all patients using absolute SC. Comparing the minimum quantifiable AC (MQAC) from in the phantom study as a threshold to the patient data, all lesions provided acceptable quantification with values > MQAC (AC 3.3–108.5 kBq/mL) for equal reconstruction and acquisition parameters. Conclusions The results demonstrated that the detection of lesions in the sub-centimetre range and a reliable quantification of 18 F/ 68 Ga-PSMA uptake using standard acquisition and reconstruction parameters within clinical PET/MRI protocols is possible. This allows for an individual assessment of potential therapy options for each patient.
No takes yet. Share an insight, caveat, or question.
Lindemann et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: