Signal-averaging and autocorrelation analysis revealed that the cardiovascular system exerts a modest but consistent influence on vocal fundamental frequency (Fo), accounting for approximately 0.5% to 20% of the absolute Fo perturbation (jitter) measured during a sustained phonation. There was also a marked trend for this percentage to decrease with increasing vocal Fo. Estimated mean "deterministic jitter" (Jd) values of 3.7 microsec (SD = 3.2) and 0.9 microsec (SD = 0.5) were derived from 6 normal male and 6 normal female subjects, respectively, with an overall mean of 2.3 microsec (SD = 2.7). These values represent approximately 6.9% of the mean total jitter for men and 2.4% of the mean total jitter for women, or about 4.6% for all subjects. The results are discussed in terms of their significance regarding more reliable vocal jitter measurement.
No takes yet. Share an insight, caveat, or question.
Orlikoff et al. (1989) studied this question.