Key result
3D MPR reduces interobserver variability versus 2D imaging for measuring mitral leaflet lengths.
Why the study?
Accurate echocardiographic assessment of mitral valve anatomy and function is essential for guiding therapeutic decision making in mitral regurgitation, especially for transcatheter mitral edge-to-edge repair where imaging precision is critical.
Does 3-dimensional transesophageal echocardiography with multiplanar reconstruction improve the quantitative assessment and precision of mitral valve leaflet length measurements compared to 2-dimensional imaging in adult patients scheduled for elective cardiac surgery?
Cohort (n=75)
No
Does 3-dimensional transesophageal echocardiography with multiplanar reconstruction improve the quantitative assessment and precision of mitral valve leaflet length measurements compared to 2-dimensional imaging in adult patients scheduled for elective cardiac surgery?
3D transesophageal echocardiography with multiplanar reconstruction provides significantly lower interobserver variability and improved precision over 2D imaging when measuring A2 and P2 mitral valve leaflet lengths, highlighting the need for standardized mitral valve imaging analysis.
Answers are grounded in this paper and cite their sources.
May improve reproducibility of mitral leaflet measurements; leaves open standardization and outcome impact before routine adoption.
OBJECTIVES Accurate echocardiographic assessment of mitral valve (MV) anatomy and function is essential for guiding therapeutic decision making in patients with mitral regurgitation. This is particularly critical for transcatheter mitral edge-to-edge repair, in which open surgical inspection is not feasible and procedural success is heavily dependent on periprocedural echocardiographic imaging. Measurements on the order of millimeters determine procedure feasibility and risk of complications. The authors hypothesized that 3-dimensional (3D) imaging with multiplanar reconstruction (MPR) would improve quantitative assessment of the MV leaflet lengths. DESIGN AND SETTING A retrospective analysis of patients scheduled for elective cardiac surgery with adequate transesophageal echocardiographic 2-dimensional (2D) mid-esophageal views and full-volume 3D datasets was performed at a single institution. PARTICIPANTS Seventy-five adult patients participated in this study. INTERVENTIONS Two- and three-dimensional diastolic leaflet lengths of the middle segment of the anterior leaflet (A2), anterior-lateral scallop of the posterior leaflet (P1), middle scallop of the posterior leaflet (P2), and posterior-medial scallop of the posterior leaflet (P3) were measured and compared using Bland-Altman and Pearson correlation statistics. Interobserver variability was evaluated in a subset of 15 patients. MEASUREMENTS AND MAIN RESULTS Correlations between 2D and 3D imaging were moderate (r = 0.41-0.74, p < 0.0001 for all). While the mean biases (differences) between 2D and 3D measures of A2 and P2 were small (0.03 and -0.07 cm, respectively), the coefficients of variation (CoVs) ranged from 19.4% to 23.7% for A2 and from 41.4% to 44.3% for P2. The mean biases between 2D and 3D measures of P1 and P3 were 0.05 and 0.04 cm, respectively, with CoVs of 59.9% and 49.6%, respectively. Interobserver variability analysis showed that 3D MPR measures of A2 (CoV, 7.3%) and P2 (CoV, 17.3%) were significantly lower (p = 0.004 and p = 0.02, respectively) than 2D measures from the mid-esophageal 4-/5-chamber and mid-esophageal long-axis windows of A2 (20.4% and 38.2%, respectively) and P2 (43.6% and 53.6%, respectively). CONCLUSIONS There were significant differences between 2D and 3D measurements of diastolic mitral leaflet lengths. While this study did not define the gold-standard measurement technique, it showed that 3D MPR with 3D feedback for precise leaflet identification of A2 and P2 resulted in improved precision based on interobserver variability and significantly lower CoV. Overall, the variability reported in this study indicates the need for well-defined standardized methods of image acquisition, image interpretation, and analysis of the MV.
No takes yet. Share an insight, caveat, or question.
Goldberger et al. (2026) conducted a cohort in Patients scheduled for elective cardiac surgery undergoing mitral valve assessment (n=75). 3-dimensional (3D) transesophageal echocardiography with multiplanar reconstruction (MPR) vs. 2-dimensional (2D) transesophageal echocardiography mid-esophageal views was evaluated on Diastolic mitral valve leaflet lengths (A2, P1, P2, P3) correlation, mean bias, coefficient of variation (CoV), and interobserver variability (r = 0.41-0.74, p=<0.0001). 3D transesophageal echocardiography with multiplanar reconstruction reduced interobserver variability for A2 and P2 vs 2D imaging.
Synapse has enriched 10 related papers. Consider them for comparative context: