Key result
High-dose adenosine administration to induce temporary asystole during endovascular AAA repair was associated with a 9.2% rate of self-limiting cardiac events.
Why the study?
Does high-dose adenosine-induced asystole safely facilitate precise stent-graft placement in patients undergoing endovascular AAA repair?
Observational (n=98)
Does high-dose adenosine-induced asystole safely facilitate precise stent-graft placement in patients undergoing endovascular AAA repair?
High-dose adenosine can safely induce temporary asystole to facilitate precise stent-graft deployment during endovascular AAA repair, with infrequent and manageable cardiac events.
Answers are grounded in this paper and cite their sources.
Supports adenosine-induced asystole for EVAR stent placement with monitoring; hypothesis-generating and requires randomized confirmation.
PURPOSE: To assess the safety and efficacy of high-dose adenosine administration to increase the precision of endovascular abdominal aortic aneurysm (AAA) repair using a balloon deployed stent-graft. METHODS: From January 1997 to March 1999, 98 AAA patients (79 men; mean age 71 years, range 62-91) were treated with balloon-expandable stent-grafts under an approved protocol. After placing a temporary transvenous ventricular lead or an external transthoracic pacing electrode, adenosine (24 mg initially) was administered in an escalating dose fashion to induce at least 10 seconds of asystole, during which the proximal stent was expanded. RESULTS: Adenosine dosages ranged from 24 to 90 mg (median 24 mg). Nine (9.2%) self-limiting cardiac events were observed: 2 (2.0%) episodes of transient myocardial ischemia, 2 (2.0%) cases of atrial fibrillation requiring cardioversion, 1 (1.0%) transient left bundle branch block lasting <10 seconds, and 4 (4.1%) prolonged periods of asystole requiring temporary pacemaker activation. There were no cases of bronchospasm or worsening obstructive pulmonary disease, and no patients required inotropic support after adenosine-induced asystole. CONCLUSIONS: Cardiac events following adenosine-induced asystole are infrequent, mild, and easily treated. The perioperative use of high-dose adenosine to ensure precise stent-graft placement appears to be a safe method of inducing temporary asystole during endovascular aortic repair.
No takes yet. Share an insight, caveat, or question.
Kahn et al. (2000) conducted an observational in Abdominal aortic aneurysm (AAA) (n=98). High-dose adenosine-induced asystole was evaluated on Self-limiting cardiac events. High-dose adenosine administration to induce temporary asystole during endovascular AAA repair was associated with a 9.2% rate of self-limiting cardiac events.