Key result
Adenosine-induced transient cardiac asystole allowed accurate deployment of balloon-expandable stent-grafts without clinical sequelae in 16 patients with aortic aneurysms.
Why the study?
Does intravenous adenosine-induced transient cardiac asystole improve precise deployment of stent-grafts in patients undergoing endovascular repair of thoracic or abdominal aortic aneurysms?
Case Report (n=16)
Does intravenous adenosine-induced transient cardiac asystole improve precise deployment of stent-grafts in patients undergoing endovascular repair of thoracic or abdominal aortic aneurysms?
Adenosine-induced transient cardiac asystole is a safe and effective technique to facilitate precise deployment of stent-grafts during endovascular aortic repair by temporarily halting systolic blood flow.
Answers are grounded in this paper and cite their sources.
May aid precise stent-graft deployment in endovascular aortic repair; hypothesis-generating and leaves open need for randomized confirmation.
Purpose: To present a cardiac asystole technique that assists in the accurate deployment of stent-grafts during endovascular repair of thoracic or abdominal aortic aneurysms. Technique: In the anesthetized patient, trial doses of intravenous adenosine are delivered until a ≥ 20-second period of asystole is recorded. The endograft procedure then proceeds until the device is ready for deployment. The predetermined dose of adenosine is administered, and the device is deployed during asystole. Adenosine-induced transient asystole has been utilized in 16 patients undergoing balloon-expandable endograft exclusion of 6 thoracic aortic and 10 abdominal aortic aneurysms. Asystole lasted for 20 to 30 seconds, during which time the devices were accurately deployed without interference from the aortic flow. There were no clinical sequelae of this technique in any patient. Conclusions: Pharmacologically induced transient asystole appears to be a safe maneuver to preclude endograft movement by systolic blood flow. The technique permits precise placement of balloon-expandable stent-grafts and is applicable to self-expanding devices as well. Interventionists may wish to incorporate adenosine-induced asystole into their aortic aneurysm exclusion procedures.
No takes yet. Share an insight, caveat, or question.
Dorros et al. (1996) conducted a case report in Thoracic or abdominal aortic aneurysms (n=16). Intravenous adenosine was evaluated on Accurate deployment of stent-grafts and clinical sequelae. Adenosine-induced transient cardiac asystole allowed accurate deployment of balloon-expandable stent-grafts without clinical sequelae in 16 patients with aortic aneurysms.
Synapse has enriched 10 related papers. Consider them for comparative context: