Demonstrates effective harmonic compliance risk evaluation in distribution networks, highlighting strong regime dependence.
Probabilistic harmonic power flow (PHPF) in distribution networks with high penetration of photovoltaic generation and electric vehicle charging requires extensive Monte Carlo simulation, particularly when compliance must be evaluated under specific operating conditions. Conventional Monte Carlo analysis provides marginal output distributions, but these cannot be directly conditioned on individual operating regimes. We develop a conditional normalizing flow (CNF) surrogate that approximates the conditional distribution of per-bus harmonic voltages and total harmonic distortion indices given uncertain system states. The surrogate achieves mean quantile errors of 0.005% and 0.011% at the 95th and 99th percentiles, respectively, a mean conditional exceedance error of 0.0009, and a probability integral transform deviation of 0.047, indicating accurate tail calibration. The results reveal strong regime dependence that is not visible in marginal statistics: at the most critical bus, the probability of exceeding the IEEE 519 limit of 8% ranges from approximately 0.10 under low-load conditions to approximately 0.91 under high-load conditions, whereas the marginal estimate is approximately 0.51. Once trained, the surrogate evaluates such conditional risk metrics in milliseconds through sampling, supporting rapid multi-scenario harmonic compliance analysis.
No takes yet. Share an insight, caveat, or question.
Enis Yazici (2026) studied this question.