Answers are grounded in this paper and cite their sources.
Demonstrates accurate estimation of valaciclovir in plasma and formulations, indicating improved quality control methods.
Introduction: The main purpose of the antiviral drug valaciclovir is to treat herpes virus infections. For quality assurance and therapeutic efficacy, accurate measurement of valaciclovir in pharmaceutical formulations and bulk is crucial. To create and verify a new chromogenic technique for determining valaciclovir utilizing and the 3-methyl-2-benzothiazolinone hydrazone (MBTH) rea-gent. The aim of this study is to develop and validate simple, precise, accurate and economical method for the estimation of valaciclovir. Methods: Valaciclovir was used to prepare and optimize MBTH for its reaction. To promote chromo-genic development, the reaction was carried out at a particular pH and temperature. Using UV-visible spectroscopy, the absorbance of the resultant chromogen was determined at an ideal wavelength. By evaluating factors including linearity, accuracy, precision, specificity, LOD, LOQ, and robustness UV-visible spectroscopy, the developed method was extended to analyzenano valaciclovir solid lipid nanoparticles, prepared by the microemulsion technique with nanoparticle size of 160nanometers. The in-house formulations were used for assay calculation. The method was validated in accordance with ICH guidelines. Results: With a correlation value (R2) of Z, a linear response was shown in the concentration range of Y=0.002x + 0.0042 with a correlation coefficient value of 0.9997. The technique showed excellent precision) and accuracy indicating the sensitivity of the approach, the LOD was found to be 1.5114 μg/mL and the LOQ was 4.58 μg/mL. Discussion: This study presents a simple, accurate, and cost-effective UV–Visible spectrophotometric method for valaciclovir using MBTH, showing excellent linearity (R² = 0.9997), accuracy (98–102% recovery), and precision (%RSD < 2%). The method compares favorably with HPLC and LC–MS, offering rapid analysis without expensive equipment. Its applicability to tablets, nanoformulations, and plasma highlights versatility, though the chromogen’s stability is limited to 2 hours, requiring prompt measurement. Overall, it is well-suited for routine quality control and adaptable to similar drugs. Conclusion: The established method offers a straightforward, quick, and accurate way to quantify valaciclovir in formulations and in bulk. Its appropriateness for regular analysis in quality control labs is confirmed by the validation results showing excellent linearity, precision, and accuracy. Its applica-bility to tablets, nanoformulations, and plasma, along with minimal resource needs, especially in re-source-limited settings.
No takes yet. Share an insight, caveat, or question.
BhavyaSri et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: