Key result
Hemodialysis is not associated with increased 1-year mortality after TAVR compared to non-hemodialysis.
Why the study?
Data on the outcomes of hemodialysis patients following TAVR with the latest generation devices remain inconsistent.
Does hemodialysis status worsen 1-year all-cause mortality in patients undergoing TAVR with the latest generation devices compared to non-hemodialysis patients?
Cohort (n=4,688)
Yes
Does hemodialysis status worsen 1-year all-cause mortality in patients undergoing TAVR with the latest generation devices compared to non-hemodialysis patients?
Answers are grounded in this paper and cite their sources.
The poor prognosis of hemodialysis patients following TAVR is largely driven by baseline comorbidities rather than hemodialysis status itself, as outcomes are similar to matched non-hemodialysis patients.
BACKGROUND: The poor prognosis of hemodialysis (HD) patients following transcatheter aortic valve replacement (TAVR) has been established; however, data on the outcomes in the latest generation of devices remain inconsistent. OBJECTIVES: The authors aimed to compare the 1-year clinical outcomes post-TAVR using the latest generation of devices in HD and non-HD patients. METHODS: From the multicenter registry, 760 HD and 3,928 non-HD patients were identified from the OCEAN-TAVI (Optimized transCathEter vAlvular iNtervention-Transcatheter Aortic Valve Implantation; UMINID:000020423) registry. To minimize differences in baseline characteristics, 1:1 propensity score matching (PSM) was performed (490 patients each). The primary clinical endpoint was all-cause mortality at 1 year. Secondary endpoints included cardiovascular death, stroke, and heart failure rehospitalization. RESULTS: In the overall cohort, during 208 (41-373) days of follow-up, HD patients had higher 1-year mortality than non-HD patients (105 of 760 [13.8%] vs 189 of 3,928 [4.8%], HR: 2.62; 95% CI: 2.13-3.23; P < 0.001); this difference was attenuated (59 of 490 [12.0%] vs 65 of 490 [13.3%], HR: 1.03; 95% CI: 0.75-1.42; P = 0.858) following well-balanced PSM. There were no significant differences in any secondary endpoints between the 2 groups after PSM; however, HD remained an independent predictor of 1-year mortality in a multivariate analysis of the cohort before PSM. CONCLUSIONS: The poor prognostic value of HD was attenuated after adjusting for baseline risk factors. These findings suggest that the poor outcomes of HD patients result from the burden of multiple comorbidities in addition to the HD risk itself. Considering TAVR as a treatment option for exceptionally high-risk populations will aid in the careful patient selection and realistic prognostic assessments.
No takes yet. Share an insight, caveat, or question.
Iwata et al. (2026) conducted a cohort in Hemodialysis patients undergoing transcatheter aortic valve replacement (n=4,688). Hemodialysis vs. Non-hemodialysis was evaluated on all-cause mortality at 1 year (HR 1.03, 95% CI 0.75-1.42, p=0.858). Hemodialysis was not associated with increased 1-year all-cause mortality after TAVR compared to non-hemodialysis following propensity score matching.
Synapse has enriched 10 related papers. Consider them for comparative context: