Key result
Higher maximum transaortic valve flow velocity is linked to ~9-fold higher odds of systolic murmurs.
Why the study?
False-positive auscultation rates due to innocent murmurs remain a concern, prompting investigation into the effect of transaortic valve flow velocity on systolic heart murmur development.
Does maximum transaortic valve flow velocity predict the presence of systolic heart murmurs in patients referred for echocardiography?
Observational (n=571)
No
Does maximum transaortic valve flow velocity predict the presence of systolic heart murmurs in patients referred for echocardiography?
Accelerated transaortic valve flow velocity is an independent predictor of systolic heart murmurs, and a cutoff of 1.7 m/s can help identify innocent murmurs before reaching the criteria for clinically significant aortic stenosis.
Answers are grounded in this paper and cite their sources.
High transaortic flow velocity may flag murmur risk; hypothesis-generating and should not change practice.
Background: Although cardiac auscultation plays an essential role in detecting valvular heart diseases, false-positive rates due to innocent heart murmurs remain a concern because accelerated transaortic valve blood flow can be a major contributor to systolic heart murmurs. In this study we investigated the effect of transaortic valve flow velocity on the development of systolic heart murmurs. Methods and Results: Cardiac auscultation was performed in 571 patients referred for echocardiography and systolic heart murmur was detected in 103 (18.0%). Maximum transaortic valve flow velocity was higher in patients with murmurs than in those without (2.02 vs. 1.34 m/s, P<0.001; area under the receiver operating characteristic curve, 0.82). A cutoff maximum transaortic flow velocity of 1.7 m/s predicted systolic heart murmurs (sensitivity, 65%; specificity, 88%). The incidence of heart murmur was associated with higher maximum transaortic valve flow velocity (<1.7 m/s, 7.3%; 1.7-2.5 m/s, 50.0%; >2.5 m/s, 73.5%). Multivariate analysis revealed the maximum transaortic valve flow velocity as an independent predictor of systolic heart murmurs (hazard ratio, 9.18; 95% confidence interval, 5.35-15.75; P<0.001). Conclusions: Accelerated transaortic valve flow velocity is an important determinant of systolic heart murmurs. Systolic heart murmurs can be heard before the transaortic valve flow velocity reaches the clinically significant aortic stenosis criterion, which can constitute a considerable number of innocent heart murmurs.
No takes yet. Share an insight, caveat, or question.
Hirayama et al. (2025) conducted an observational in Systolic heart murmurs (n=571). Maximum transaortic valve flow velocity vs. Lower maximum transaortic valve flow velocity was evaluated on Presence of systolic heart murmurs (OR 9.18, 95% CI 5.35-15.75, p=<0.001). Higher maximum transaortic valve flow velocity was an independent predictor of systolic heart murmurs.
Synapse has enriched 10 related papers. Consider them for comparative context: