Why the study?
Does an aortic mechanical valve prosthesis alter ascending aorta flow profiles compared to normal native valves?
Does an aortic mechanical valve prosthesis alter ascending aorta flow profiles compared to normal native valves?
Mechanical aortic valve prostheses significantly alter ascending aortic flow profiles, increasing peak flow velocity, closing volume, and diastolic leakage compared to native valves as measured by MRI velocity mapping.
Answers are grounded in this paper and cite their sources.
Higher prosthetic velocities observed cross-sectionally should not change practice; leaves open outcome associations and need for longitudinal studies.
OBJECTIVES: Magnetic resonance (MRI) velocity mapping was used to evaluate non-invasively the flow profiles of the ascending aorta in normal volunteers and in patients with an aortic (mechanical) valve prosthesis. BACKGROUND: In patients with artificial aortic valves the flow profile in the ascending aorta is severely altered. These changes have been associated with an increased risk of thrombus formation and mechanical hemolysis. METHODS: Velocity profiles were determined 30 mm distal to the aortic valve in six healthy volunteers and seven patients with aortic valve replacement (replacement within the last 2 years) using ECG triggered phase contrast MRI. Peak flow, mean flow and mean reverse flow were measured in intervals of 25 ms during the entire heart cycle. Systolic reverse flow, end-systolic closing and diastolic leakage volume were calculated for all subjects. RESULTS: Peak flow velocity during mid-systole was significantly higher in patients with valvular prosthesis than in normals (mean + SD, 1.9 +/- 0.4 m/s vs. 1.2 +/- 0.03 m/s, P < 0.001) with a double peak and a zone of reversed flow close to the inner (left lateral) wall of the ascending aorta of the patients. Closing volume was significantly larger in patients than in controls (-3.3 +/- 1.2 ml/beat vs. -0.9 +/- 0.5 ml/beat; P < 0.001). There was reverse flow during systole in valvular patients amounting to 15.7 +/- 6.7% of total cardiac output compared to 2.3 +/- 1.2% in controls (P < 0.001). Diastolic mean flow was negative in patients after valve replacement but not in controls (-11.0 +/- 15.2 ml/beat vs. 6.8 +/- 3.2 ml/beat; P < 0.01). CONCLUSIONS: The following three major quantitative observations have been made in the present study: (1) Mechanical valve prostheses have an increased peak flow velocity with a systolic reverse flow at the inner (left lateral) wall of the ascending aorta. (2) A double peak flow velocity pattern can be observed in patients with bileaflet (mechanical) prosthesis. (3) The blood volume required for leaflet closure and the diastolic leakage blood volume are significantly higher for the examined bileaflet valve than for native heart valves.
No takes yet. Share an insight, caveat, or question.
Botnar et al. (2000) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: