Key result
Personalized left atrial computational models show limited agreement with clinical measurements for fractionation and conduction changes.
Answers are grounded in this paper and cite their sources.
Personalized left atrial computational models require improved restitution modeling and functional markers to accurately capture beat-dependent conduction dynamics and arrhythmogenic substrates.
and fractionation showed limited agreement (correlation coefficients $< $ 0.4 and 0.25, respectively), reflecting sensitivity to microstructural detail and spatial uncertainty. Notably, the models did not consistently reproduce TE-induced conduction changes observed clinically, underscoring the need for improved restitution modelling to better capture beat-dependent conduction dynamics. Overall, personalized LA models captured global conduction behaviour, but were weakly constrained by clinical measurements, highlighting uncertainty associated with computational models construction. These results support personalization strategies grounded in functional markers, such as restitution or frequency-domain features, combined with coarse structural information to better identify arrhythmogenic substrates.
No takes yet. Share an insight, caveat, or question.
Celotto et al. (2026) studied Atrial arrhythmogenic substrates. Personalized left atrial computational models vs. Clinical measurements was evaluated on Agreement of fractionation and conduction changes (correlation coefficients < 0.4 and 0.25). Personalized left atrial computational models showed limited agreement with clinical measurements for fractionation and TE-induced conduction changes.