Key result
Relocation of superficial pacing leads to a subpectoral pocket using a tunneling technique successfully resolved pain and erosion concerns in 100% of patients (14/14) by 3 months.
Why the study?
Does relocation of prepectoral leads and generator to a subpectoral pocket via a tunneling technique improve pain and erosion in patients with superficial CIED implants?
Observational (n=14)
Does relocation of prepectoral leads and generator to a subpectoral pocket via a tunneling technique improve pain and erosion in patients with superficial CIED implants?
Relocating superficial CIED leads to a subpectoral pocket using a tunneling technique is a safe and effective method to relieve pain and erosion with minimal pectoral trauma.
Answers are grounded in this paper and cite their sources.
May be feasible for subpectoral CIED relocation in select patients; leaves open need for larger prospective validation.
BACKGROUND: Methodology specific for moving superficial chronically implanted transvenous pacing leads to a subpectoral pocket is not described in the literature. Relocation of prepectoral leads and generator to a submuscular pocket for relief of erosion and pain with minimal pectoral trauma is possible by applying a variant of a previously described submammary tunneling technique. METHODS: All patients presenting for device follow-up, elective battery replacement, or system upgrade over an 8-month period were considered for relocation if experiencing significant thinning or pain over their prepectoral implant. Those selected for relocation then had their system moved subpectorally via the tunneling technique. Patients were followed for 6 months postoperatively for procedurally related complications and resolution of preprocedure symptoms. RESULTS: Thirty-two leads in 14 patients were all successfully relocated. Of the relocated leads, five (16%) were a three-pin connector implantable cardioverter defibrillator lead. Three patients (21%) in the group required short-term prescription analgesia in the immediate postdischarge period. Pain and erosion concerns abated in the study group by the 3-month follow-up. CONCLUSIONS: Relocation of superficial pacing leads with CIED generator to a subpectoral pocket facilitated by this tunneling method is successful, safe, and can accommodate single and multipin leads with minimal pectoral trauma and no nerve damage.
No takes yet. Share an insight, caveat, or question.
Aaron Hesselson (2018) conducted an observational in Thinning or pain over prepectoral CIED implant (n=14). Relocation of superficial pacing leads to a subpectoral pocket via tunneling technique was evaluated on Procedurally related complications and resolution of preprocedure symptoms. Relocation of superficial pacing leads to a subpectoral pocket using a tunneling technique successfully resolved pain and erosion concerns in 100% of patients (14/14) by 3 months.