Key result
Catheter ablation without ICE and 3D mapping linked to ~251% higher 30-day complication risk.
Why the study?
Does the use of intracardiac echocardiography and 3D mapping during catheter ablation reduce 30-day complications and death in older patients with atrial fibrillation?
Cohort (n=206,252)
Yes
Does the use of intracardiac echocardiography and 3D mapping during catheter ablation reduce 30-day complications and death in older patients with atrial fibrillation?
The use of intracardiac echocardiography and 3D mapping during catheter ablation for atrial fibrillation in older adults is associated with a significantly lower risk of 30-day complications and mortality.
Answers are grounded in this paper and cite their sources.
May support ICE/3D mapping to lower CA complications; leaves open need for randomized confirmation before practice change.
Aim: This retrospective cohort study assessed differences in procedure-related complications and death among old patients with atrial fibrillation (AF) undergoing catheter ablation (CA) procedure with versus without use of intracardiac echocardiography (ICE) and advanced three-dimensional (3D) electroanatomical mapping. Materials & methods: Using the Medicare Database, a retrospective cohort of AF patients ≥65 years of age who underwent CA procedure were identified, and categorized into two cohorts: CA without ICE/3D mapping versus CA with ICE/3D mapping. Outcomes including a composite of complications (any), cardiac perforation, esophageal fistula and death, respectively, in the 30-day period post-CA were assessed. Inverse probability of treatment weighting method was used for covariate balancing. Cox regression models were performed to evaluate outcomes. Results: There were 35,490 patients in CA without ICE/3D mapping cohort and 170,762 in the CA with ICE/3D mapping cohort. Cox regression model revealed that patients who underwent CA without ICE/3D mapping use were ∼3.5-times more likely to have 30-day any complication versus those who had CA with ICE/3D mapping (7.3% vs 2.2%, log-rank test p < 0.001; hazard ratio: 3.507; 95% CI: 3.307–3.720, p < 0.001). The incidence of cardiac perforation (2.5% vs 0.1%, log-rank test p < 0.001), atrio-esophageal fistula (0.03% vs 0.01%, log-rank test p = 0.03) and death (1.6% vs 0.2%, log-rank test p < 0.001) were significantly higher among patients without ICE/3D mapping versus those who had CA with ICE/3D mapping. Conclusion: The absence of ICE and 3D mapping during CA procedures was associated with significantly increased risk of complications and death among Medicare eligible patients with AF.
No takes yet. Share an insight, caveat, or question.
Rong et al. (2026) conducted a cohort in Atrial fibrillation (n=206,252). Catheter ablation without intracardiac echocardiography (ICE) and 3D mapping vs. Catheter ablation with ICE and 3D mapping was evaluated on Composite of any complications in the 30-day period post-catheter ablation (HR 3.507, 95% CI 3.307-3.720, p=<0.001). Catheter ablation without ICE and 3D mapping was associated with a higher risk of 30-day complications compared to ablation with ICE/3D mapping.