Key result
TAVI reduces functional MR and TR in a severe aortic stenosis case.
Case Report (n=1)
Answers are grounded in this paper and cite their sources.
TAVI using the Navitor Vision valve in a patient with a small annulus and complex multivalvular disease facilitated favorable hemodynamic outcomes and reverse remodeling of concomitant MR and TR.
Background Concomitant mitral regurgitation (MR) and tricuspid regurgitation (TR) are frequently encountered in patients with severe aortic stenosis (AS) and are associated with adverse clinical outcomes after transcatheter aortic valve implantation (TAVI). However, the impact of transcatheter heart valve selection on postprocedural multivalvular hemodynamics remains incompletely understood. Case Summary An 87-year-old woman with symptomatic low-flow, low-gradient aortic stenosis (AS) complicated by moderate-to-severe mitral regurgitation (MR) and severe tricuspid regurgitation (TR) was admitted with refractory heart failure despite intensive medical therapy. Given her advanced age, frailty, and high surgical risk, transfemoral transcatheter aortic valve implantation (TAVI) was performed using a 23-mm Navitor™ Vision valve (Abbott Structural Heart, Santa Clara, CA, USA). Valve selection was guided by the presence of a small aortic annulus and the need to balance optimal haemodynamic performance with minimisation of potential mitral valve interaction. The procedure was successfully completed without significant residual transvalvular gradient or paravalvular leakage. Following TAVI, relief of afterload was achieved, leading to improvement in functional MR and TR, with discontinuation of inotropic support. Follow-up echocardiography demonstrated reduction in both MR and TR, accompanied by a decrease in right ventricular systolic pressure. Conclusion We report a case of symptomatic low-flow, low-gradient AS with concomitant MR and TR that was successfully treated with TAVI using a Navitor Vision valve. In patients with small annuli and complex multivalvular disease, careful transcatheter heart valve selection and procedural optimisation may facilitate favourable haemodynamic outcomes and reverse remodelling.
No takes yet. Share an insight, caveat, or question.
Otani et al. (2026) conducted a case report in Symptomatic low-flow, low-gradient aortic stenosis complicated by moderate-to-severe mitral regurgitation and severe tricuspid regurgitation (n=1). Transcatheter aortic valve implantation (TAVI) using a Navitor Vision valve was evaluated on Improvement in functional mitral and tricuspid regurgitation. TAVI using a 23-mm Navitor Vision valve successfully reduced concomitant functional mitral and tricuspid regurgitation in an 87-year-old woman with severe aortic stenosis.
Synapse has enriched 10 related papers. Consider them for comparative context: