Key result
CMC-free single-catheter RF PVI yields similar 12-month atrial arrhythmia recurrence versus a CMC-guided workflow.
Why the study?
Does a CMC-free single-catheter workflow improve procedural efficiency and preserve efficacy compared to a CMC-guided workflow in patients undergoing first-time radiofrequency pulmonary vein isolation for atrial fibrillation?
Cohort (n=326)
Single-blind
No
Does a CMC-free single-catheter workflow improve procedural efficiency and preserve efficacy compared to a CMC-guided workflow in patients undergoing first-time radiofrequency pulmonary vein isolation for atrial fibrillation?
Answers are grounded in this paper and cite their sources.
Omitting the circular mapping catheter during first-time radiofrequency pulmonary vein isolation improves procedural efficiency without compromising 12-month freedom from atrial arrhythmias.
Background Circular mapping catheters (CMC) are used to confirm pulmonary vein isolation (PVI) in radiofrequency (RF) ablation for atrial fibrillation (AF), but may be unnecessary in CLOSE-style point-by-point workflows. We evaluated whether omitting the CMC preserves efficacy and improves efficiency in first-time PVI. Methods We conducted a single-center, hybrid prospective–retrospective comparison of consecutive first-time PVI cases. A CMC-guided cohort ( n = 81) underwent point-by-point RF PVI; operators were blinded to CMC electrograms during ablation and were unblinded after PVI had been verified with the ablation catheter. A subsequent CMC-free cohort ( n = 245) used ablation-catheter–only verification. The primary endpoint was 12-month freedom from atrial arrhythmia (≥30 s) after a 90-day blanking period; Cox and negative binomial models were applied. Procedural metrics were secondary endpoints. Results CMC-free cases had shorter procedures [105 (90, 120) vs. 120 (110, 135) min, p < 0.001], lower fluoroscopy [4 (3, 6) vs. 6 (5, 9) min, p < 0.001], and lower radiation dose [150 (96, 254) vs. 220 (167, 399) cGy·cm 2 , p < 0.001]. RF time and energy were reduced [2,083 (1,806, 2,493) vs. 2,343 (1,977, 2,611) s, p = 0.026; 71,582 (60,527, 85,399) vs. 77,335 (68,009, 87,376) J, p = 0.035]. Twelve-month efficacy was comparable (adjusted HR: 1.03, 95% CI: 0.58–1.84; p = 0.92); recurrences did not differ (adjusted IRR: 0.61, 95% CI: 0.30–1.21; p = 0.16). On post-ablation unblinding in the CMC-guided arm, residual PV conduction was detected in 11/321 veins (3.4%). Conclusion In CLOSE-style first-time RF PVI, a CMC-free, single-catheter workflow was associated with improved procedural efficiency and no significant difference in observed 12-month arrhythmia outcomes. These findings are hypothesis-generating. Prospective randomized studies are needed to confirm the safety and efficacy of this approach.
No takes yet. Share an insight, caveat, or question.
Zamponi et al. (2026) conducted a cohort in Atrial fibrillation (n=326). CMC-free single-catheter radiofrequency pulmonary vein isolation vs. CMC-guided radiofrequency pulmonary vein isolation was evaluated on 12-month recurrence of atrial arrhythmia (≥ 30 s) after a 90-day blanking period (HR 1.03, 95% CI 0.58-1.84, p=0.92). A CMC-free, single-catheter radiofrequency pulmonary vein isolation workflow resulted in a similar 12-month atrial arrhythmia recurrence rate compared to a CMC-guided strategy.
Synapse has enriched 10 related papers. Consider them for comparative context: