June 27, 2026EP Europace0 citationsOpen Access

Safety, efficacy and reproducibility of a simplified strategy to achieve pulmonary vein isolation using radiofrequency ablation

View Full Paper
OBO BastidasJMJ E MarinLRL M Ruiz

Key Result

A simplified radiofrequency ablation strategy for pulmonary vein isolation achieved 86% freedom from atrial arrhythmia recurrence at 1 year, irrespective of operator experience or fellow participation.

Key Points

  • This research aims to evaluate the safety, efficacy, and reproducibility of a simplified strategy for achieving pulmonary vein isolation.
  • Included 771 patients undergoing first-time pulmonary vein isolation from January 2022 to May 2025.
  • Performed point-by-point radiofrequency ablation under general anesthesia with a target interlesion distance of 3 mm.
  • Followed patients with Holter monitoring at 3, 6, 12 months, then biannually.
  • At one-year follow-up, 86% of patients were free from all atrial arrhythmia recurrence.
  • Procedural time averaged 100 minutes, with 48.6% cases completed without fluoroscopy.
  • Only 0.4% of patients developed pulmonary vein stenosis, with no cases of atrial-esophageal fistula.

Study Design

Type

Cohort (n=771)

Structured PICO

Does a simplified radiofrequency ablation strategy with 3 mm interlesion distance prevent atrial arrhythmia recurrence in patients undergoing first-time pulmonary vein isolation?

P
Population
771 patients with atrial fibrillation undergoing first-time pulmonary vein isolation using a simplified radiofrequency ablation approach, followed for 1 year.
E
Exposure
Simplified approach to pulmonary vein isolation (PVI) using point-by-point radiofrequency ablation (RFA) with a target interlesion distance of 3 mm, eliminating waiting periods, adenosine testing, and remapping.
O
Outcome
Freedom from all atrial arrhythmia recurrence at 1-year follow-uphard clinical

A simplified radiofrequency ablation strategy for pulmonary vein isolation using a 3 mm interlesion distance achieves high efficacy and safety, with reproducible results regardless of operator experience.

Abstract

Abstract Introduction Pulmonary vein isolation (PVI) is currently the cornerstone for atrial fibrillation (AF) ablation, with point-by-point radiofrequency ablation (RFA) frequently performed. By reducing interlesion distance, PVI can be improved and other frequently used strategies (waiting period, adenosine testing, remapping) can be avoided without any impact on procedural outcomes. Purpose To describe the safety, efficacy and reproducibilility of a simplified approach to pulmonary vein isolation, based on the use of an interlesion distance of 3 mm. Methods Patients undergoing first-time PVI between January 2022 and May 2025 were included. PVI was performed using point-by-point RFA under general anesthesia using high-frequency low-tidal volume ventilation, performing wide antral catheter ablation using 40W. The simplified approach included: 1. Two femoral venous accesses through the right groin (1 for the transeptal sheath, 1 for intracardiac echocardiography); 2. A single transeptal puncture; 3. PVI with a target interlesion distance of 3 mm; 4. Evaluating entrance and exit block using the ablation catheter. All ablations were performed guided by lesion indexes; lesion contiguity in the posterior wall was not obligatory, to avoid heat stacking. If first pass isolation was not achieved, additional lesions were delivered at the site of earliest activation. Patients were followed with holter monitoring or device interrogation at 3,6,12 months, and every 6 months thereafter. Results A total of 771 patients (female n=264, age 62.5±11.4 years) were included (Table 1). Persistent AF was present in 321 (41.6%) of patients, severe left atrial dilation (defined as a left atrial indexed volume ≥48 mL/m2) in 158 (20.5%), heart failure in 173 (22.4%), and an implantable cardiac electronic device in 116 (15%) patients. Procedural time was 10078-130 min., with 48.6% of cases performed without fluoroscopy. During follow-up, there were no cases of atrial-esophageal fistula, with 3 patients (0.4%) presenting pulmonary vein stenosis which did not require intervention. At 1-year follow-up, 86% of patients were free from all atrial arrhythmia recurrence. To evaluate reproducibility, we evaluated if operator experience or fellow participation during the ablation had a significant impact on arrhythmia recurrence. There were no significant differences in patients characteristics for any of the comparison groups. During follow-up, there were no significant differences in outcomes when comparing by operator experience (Figure 1A) or by fellow participation during the ablation procedure (Figure 1B). Conclusions A simplified approach relying on minimal interlesion distance while eliminating waiting periods, adenosine testing, and remapping, is both safe and effective during RFA PVI, demonstrating a low rate of arrhythmia recurrence. Moreover, similar results are observed irrespective of operator experience or fellow participation during the ablation procedure.Table 1Figure 1

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Bastidas et al. (2026) conducted a cohort in Atrial fibrillation (n=771). Simplified approach to pulmonary vein isolation using radiofrequency ablation was evaluated on Freedom from all atrial arrhythmia recurrence at 1-year follow-up. A simplified radiofrequency ablation strategy for pulmonary vein isolation achieved 86% freedom from atrial arrhythmia recurrence at 1 year, irrespective of operator experience or fellow participation.

synapsesocial.com/papers/6a3f97e8125782b61d865ad6https://doi.org/10.1093/europace/euag105.502