Observational (n=22)
Odds Ratio: 0.911
p-value: p=0.016
A significant proportion of patients develop HALT after TTVR with the Evoque system despite anticoagulation, and lower preprocedural LV stroke volume is an independent predictor of this phenomenon.
No abstract yet. The journal hasn't published one we can show.
No takes yet. Share an insight, caveat, or question.
Garg et al. (2026) conducted an observational in Transcatheter tricuspid valve replacement (TTVR) (n=22). Preprocedural left ventricular stroke volume (LVSV) was evaluated on Hypoattenuated leaflet thickening (HALT) (OR 0.911, p=0.016).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: