Assesses image quality and partial-volume effects in small-animal SPECT and PET, suggesting reliable evaluation methods.
The partial-volume effect (PVE) is a major factor affecting quantitative accuracy in small-animal SPECT and PET imaging, leading to underestimation of activity in hot-rod images and overestimation in cold-rod images. However, a phantom capable of assessing image quality, including the PVE in both hot and cold regions, has not been available. This study aimed to determine whether a newly developed phantom can accurately evaluate image quality, including the PVE of hot- and cold-rod images, in small-animal SPECT and PET systems. Methods: The phantom consisted of a cylindric pool and rod sections. The rod section included 6 hot rods and 6 cold rods with diameters of 1–6 mm. The rod and pool sections were filled with solutions containing 99mTc and ¹⁸F, respectively. In the hot-rod section, the radioactive concentration ratio between rods and background was set to 4:1. Images were acquired for 30 min and reconstructed with a voxel size of 0.8 mm using a pixel-based ordered-subset expectation maximization algorithm. Image contrast, absolute and inverse recovery coefficients (RCs) (indicators of the PVE), and percent coefficient of variation (%CV) and signal-to-noise ratio (indicators of uniformity) were evaluated for both hot and cold rods. Results: The contrast of the hot rod for 99mTc and ¹⁸F showed lower values with decreasing rod diameters. Furthermore, the 99mTc image demonstrated a higher contrast than the ¹⁸F image and approached the true contrast. The cold-rod contrasts with 99mTc and ¹⁸F followed a similar trend. The RCs of 99mTc and ¹⁸F were lower as rod diameters decreased. The radioactive concentration in the 40-mm pool section was similar to that of the 6-mm hot rod for both radionuclides. The inverse RC was lower with a decreasing cold-rod diameter. Moreover, cold-rod images with ¹⁸F demonstrated lower inverse RCs than with 99mTc. The %CVs for the 99mTc and ¹⁸F images were 3.49% ± 0.03% and 6.29% ± 0.07%, respectively, with the 99mTc image displaying a lower %CV compared with the ¹⁸F image. Conclusion: We developed a phantom that allows the evaluation of physical phenomena in small-animal SPECT and PET images, providing reliable assessment of image contrast, PVE, and uniformity in both hot and cold rods.
No takes yet. Share an insight, caveat, or question.
Shibutani et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: