Key result
Anxiety was associated with an increased risk of ventricular arrhythmias (HR 1.017; 95% CI 1.005-1.028; p=0.005) and mortality (HR 1.038; 95% CI 1.014-1.063; p=0.002) 1 year after ICD implantation.
Why the study?
Does high anxiety increase the risk of ventricular arrhythmias and mortality in patients with an implantable cardioverter defibrillator?
Cohort (n=1,012)
Does high anxiety increase the risk of ventricular arrhythmias and mortality in patients with an implantable cardioverter defibrillator?
Hazard Ratio: 1.017 (95% CI 1.005–1.028)
p-value: p=0.005
Baseline anxiety is independently associated with a significantly increased risk of ventricular arrhythmias and mortality at 1 year in patients with an ICD.
Anxiety screening may flag higher-risk ICD patients; leaves open whether intervention improves outcomes.
OBJECTIVE: A subgroup of patients with an implantable cardioverter defibrillator (ICD) experiences anxiety after device implantation. The purpose of the present study was to evaluate whether anxiety is predictive of ventricular arrhythmias and all-cause mortality 1 year post ICD implantation. METHODS: A total of 1012 patients completed the state version of the State-Trait Anxiety Inventory at baseline. The end points were ventricular arrhythmias and mortality the first year after ICD implantation. RESULTS: Within the first year after ICD implantation, 19% of patients experienced a ventricular arrhythmia, and 4% died. Anxiety was associated with an increased risk of ventricular arrhythmias (hazard ratio [HR] = 1.017; 95% confidence interval [CI] = 1.005-1.028; p = .005) and mortality (HR = 1.038; 95% CI = 1.014-1.063; p = .002) in adjusted analysis. Patients with anxiety (highest tertile) had a 1.9 increased risk for ventricular arrhythmias (95% CI = 1.329-2.753; p =.001) and a 2.9 increased risk for mortality (95% CI = 1.269-6.677; p = .01) compared with patients with low anxiety (lowest tertile). Among 257 patients with cardiac resynchronization therapy, anxiety was associated with mortality (HR = 5.381; 95% CI = 1.254-23.092; p = .02) after adjusting for demographic and clinical covariates. CONCLUSIONS: Anxiety was associated with an increased risk of ventricular arrhythmias and mortality 1 year after ICD implantation, independent of demographic and clinical covariates. Monitoring and treatment of anxiety may be warranted in a selected subgroup of high-risk patients with an ICD.
No takes yet. Share an insight, caveat, or question.
Habibović et al. (2012) conducted a cohort in Implantable cardioverter defibrillator (ICD) (n=1,012). Anxiety vs. Low anxiety was evaluated on Ventricular arrhythmias 1 year post ICD implantation (HR 1.017, 95% CI 1.005-1.028, p=0.005). Anxiety was associated with an increased risk of ventricular arrhythmias (HR 1.017; 95% CI 1.005-1.028; p=0.005) and mortality (HR 1.038; 95% CI 1.014-1.063; p=0.002) 1 year after ICD implantation.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: