Key result
Zero-fluoroscopy SVT ablation limits annual operator radiation exposure to ~9 µSv, well below European limits.
Why the study?
Exposure to ionizing radiation in electrophysiology can significantly affect the professional careers of women of reproductive age.
Does a zero or near-zero fluoroscopy approach keep annual radiation exposure below the 1 mSv limit for female operators performing RFCA for SVT?
Observational (n=710)
Yes
Does a zero or near-zero fluoroscopy approach keep annual radiation exposure below the 1 mSv limit for female operators performing RFCA for SVT?
Adopting a zero or near-zero fluoroscopy approach for SVT ablation keeps annual radiation exposure for female operators well below the European 1 mSv safety limit, regardless of operator experience.
Answers are grounded in this paper and cite their sources.
Supports safe radiation exposure for female operators using near-zero fluoroscopy; leaves open need for prospective trials before wider adoption.
Background Exposure to ionizing radiation in electrophysiology can have a significant impact on the professional careers of women of reproductive age. Purpose The aim of our registry was to quantify the total amount of X-rays, potentially absorbed over the course of a working year by a female operator of reproductive age performing consecutive radiofrequency catheter ablation (RFCA) for supraventricular tachycardia (SVT) adopting a zero or near-zero approach. Methods Twelve centers across Europe took part in the study. All procedures were performed with a zero or near-zero approach, using a 3D mapping system, guided by the ALARA principles. Results Overall, 710 RFCA procedures were performed. The mean age of the operators was 38±7 years. The mean procedure time was 80±35 min with a mean fluoroscopy time of 48±148 s. The mean operator annual DAP was 46.7±79.5 Gycm² and the mean operator annual Effective Dose was 9.34±15.9 µSV. The yearly Effective Dose did not reach the 1 mSv cut-off in any operator. The mean DAP did not differ among the several operators, and was not affected by the overall operator’s experience in performing SVT RFCA, as well as the operator’s volume of yearly procedures performed with a zero or near-zero approach. Conclusions The total amount of X-rays, potentially absorbed over the course of a working year by a female operator of reproductive age performing consecutive RFCA for SVT adopting a zero or near-zero approach, is inferior to the established European limit of 1 mSv, and is not affected by the operator’s experience.
No takes yet. Share an insight, caveat, or question.
Poggi et al. (2026) conducted an observational in Supraventricular tachycardia (n=710). Zero or near-zero fluoroscopy approach was evaluated on Mean operator annual Effective Dose. A zero or near-zero fluoroscopy approach for SVT ablation by female operators resulted in a mean annual effective dose of 9.34 µSV, remaining below the 1 mSv European limit.
Synapse has enriched 10 related papers. Consider them for comparative context: