Key result
Identifying PV triggers during de novo AF ablation is linked to ~23% lower atrial arrhythmia recurrence.
Why the study?
The clinical significance of identifying pulmonary vein triggers during catheter ablation for AF remains unclear.
Does the identification of pulmonary vein triggers during de novo catheter ablation predict reduced recurrence of atrial arrhythmia in patients with atrial fibrillation?
Cohort (n=1,420)
Does the identification of pulmonary vein triggers during de novo catheter ablation predict reduced recurrence of atrial arrhythmia in patients with atrial fibrillation?
Answers are grounded in this paper and cite their sources.
The identification of pulmonary vein triggers during de novo catheter ablation for atrial fibrillation is an independent predictor of lower atrial arrhythmia recurrence, likely reflecting earlier-stage disease prior to advanced structural remodeling.
Background Pulmonary veins (PVs) are key sources of ectopic activity initiating atrial fibrillation (AF). However, the clinical significance of PV triggers identified during catheter ablation (CA) remains unclear. This study aimed to assess whether the identification of spontaneous PV triggers during de novo CA is associated with long-term clinical outcomes. Methods We retrospectively analyzed 1,420 patients (72.3% male, 59.6±11.4 years) who underwent de novo CA for AF between January 2015 and July 2022. All patients received wide circumferential pulmonary vein isolation (PVI) without substrate modification. PV triggers were identified based on spontaneous or incidentally provoked ectopic activity. Extra-PV trigger ablation was performed at the operator’s discretion. Results PV trigger were identified in 537 patients (37.8%). During a mean follow-up of 28.3±21.3 months, patients with identified PV triggers had lower recurrence of atrial arrhythmia than those without (22.5% vs. 30.7%, P<0.001). In Multivariate Cox regression analysis, PV trigger presence was independently associated with reduced recurrence (Hazard ratio [HR] 0.77, 95% Confidence interval [CI] 0.61-0.97, P=0.027), whereas persistent AF, left atrial (LA) diameter ≥50mm, and extra-PV triggers were associated higher recurrence. Logistic regression showed that PV trigger presence was associated with a LA volume ≤100ml, paroxysmal AF, and left ventricular ejection fraction ≥50%. Conclusion The identification of PV triggers during CA is independently associated with favorable clinical outcomes. This finding suggests that early intervention before advanced structural and electrical remodeling may improve rhythm control by targeting triggers confined to the PVs.
No takes yet. Share an insight, caveat, or question.
Choi et al. (2026) conducted a cohort in Atrial fibrillation (n=1,420). Identification of pulmonary vein triggers vs. No identification of pulmonary vein triggers was evaluated on Recurrence of atrial arrhythmia (HR 0.77, 95% CI 0.61-0.97, p=0.027). Identification of pulmonary vein triggers during de novo catheter ablation for AF was associated with reduced recurrence of atrial arrhythmia.
Synapse has enriched 10 related papers. Consider them for comparative context: