Key result
Mid-term lead tip-to-LV distance >2 mm linked to ~640% greater risk of LBB capture loss.
Why the study?
Left bundle branch pacing preserves physiological activation, but data on the long-term durability of conduction system capture remain limited.
Does a mid-term lead tip-to-left ventricular cavity distance >2 mm predict long-term loss of left bundle branch capture in patients with bradycardia undergoing LBBP?
Cohort (n=34)
Yes
Does a mid-term lead tip-to-left ventricular cavity distance >2 mm predict long-term loss of left bundle branch capture in patients with bradycardia undergoing LBBP?
A mid-term lead tip-to-left ventricular cavity distance >2 mm strongly predicts long-term loss of left bundle branch capture, emphasizing the importance of optimal lead depth during implantation.
Answers are grounded in this paper and cite their sources.
May warrant closer LBB pacing follow-up for capture loss risk; leaves open prospective validation of lead positioning thresholds.
Background and Aims Left bundle branch pacing (LBBP) has been an emerging pacing modality that preserves physiological activation. However, data on the long-term durability of conduction system capture remain limited. This study aimed to assess the long-term stability of LBBP capture and identify predictors of capture loss. Methods This study analyzed data from the multicenter, prospective IMAGE-LBBP cohort. Of 50 patients with bradycardia who underwent mid-term cardiac computed tomography imaging after LBBAP implantation, 34 with confirmed LBBP and analyzable imaging at mid-term were included in the long-term analysis. Lead-related complications and pacing parameters were prospectively collected. The main outcome was new-onset loss of LBB capture after the mid-term assessment. Results During a mean follow-up of 60.1±7.9 months, new-onset LBB capture loss occurred in 20.6% (7/34) of patients. Multivariate Cox regression identified mid-term lead tip–to–left ventricular cavity (tip–LV) distance as an independent predictor of long-term capture loss (HR = 2.26; 95% CI, 1.17–4.35; P = 0.015). A cutoff of 2.0 mm yielded high predictive accuracy (AUC = 0.881; 95% CI, 0.756–1.0), with 85.7% sensitivity and 77.8% specificity. Kaplan–Meier analysis showed a significantly higher risk of capture loss in patients with a tip–LV distance >2 mm compared to those with ≤2 mm (HR = 7.4; 95% CI, 1.6–34.8; log-rank P = 0.012). Conclusion LBB capture loss is progressive and occurs in approximately 20% of patients during long-term follow-up. A tip–LV distance >2 mm at mid-term is strongly associated with subsequent capture loss, highlighting the importance of optimal lead implantation and mid-term anatomical assessment to ensure durable conduction system pacing.
No takes yet. Share an insight, caveat, or question.
Cai et al. (2026) conducted a cohort in Bradycardia with confirmed left bundle branch pacing (n=34). Mid-term lead tip-to-left ventricular cavity distance >2 mm vs. Mid-term lead tip-to-left ventricular cavity distance ≤2 mm was evaluated on New-onset loss of LBB capture after the mid-term assessment (HR 7.4, 95% CI 1.6-34.8, p=0.012). A mid-term lead tip-to-left ventricular cavity distance >2 mm was associated with a significantly higher risk of long-term left bundle branch capture loss compared to ≤2 mm (HR 7.4; 95% CI 1.6-34.8).