Key result
Secondary prevention ICDs in arrhythmic mitral valve prolapse deliver appropriate therapies at ~8 per person-year.
Why the study?
Data on the recurrence of life-threatening ventricular arrhythmia following ICD implantation for secondary prevention in patients with mitral valve prolapse are not available.
What is the incidence and type of recurrent ventricular arrhythmia in patients with arrhythmic mitral valve prolapse and an ICD for secondary prevention?
Meta-Analysis (n=163)
What is the incidence and type of recurrent ventricular arrhythmia in patients with arrhythmic mitral valve prolapse and an ICD for secondary prevention?
Patients with arrhythmic mitral valve prolapse and an ICD for secondary prevention have a high rate of recurrent ventricular arrhythmias, predominantly polymorphic VT or VF.
Answers are grounded in this paper and cite their sources.
Highlights substantial long-term VA recurrence; leaves open prospective trials on prevention strategies.
Background Mitral valve prolapse is a benign in the majority of cases, however, life-threatening ventricular arrhythmia (VA), requiring the implantation of an implantable cardioverter-defibrillator (ICD) for secondary prevention, is reported in a subset of patients. Data on the recurrence of life-threatening VA following ICD implantation are not available. Purpose This study aimed to evaluate the incidence of appropriate ICD therapies and type of arrythmia recurrence in arrhythmic mitral valve prolapse (AMVP) patients with an ICD implanted for secondary prevention. Methods A systematic literature search was conducted in PubMed/MEDLINE and EMBASE databases until January 2025. Studies reporting the incidence of appropriate ICD therapy in AMVP patients were included. Results A total of 9 studies met the inclusion criteria resulting in 163 AMVP patients with ICDs for secondary prevention. The mean age was 41.8 years, with 55.8% of patients being female. Over a weighted mean follow-up of 4.9±3.1 years, 33.4% (95%CI: 20.2-46.4) of the patients experienced recurrence of VA. The pooled incidence of appropriate ICD therapies during follow-up was 7.8 per person-year (95% CI: 5.0–10.6, I2: 30.1%). Regarding the type of arrhythmic recurrence, the majority of arrhythmias (53.3%, 95% CI: 43.8%–62.9%) were in the form of ventricular fibrillation or polymorphic ventricular tachycardia (VT), while the remaining recurrent arrhythmias were reported as monomorphic VT Conclusion AMVP patients with ICDs for secondary prevention exhibit a high risk of recurrent arrhythmias, with recurrences in the form of polymorphic VA occurring in more than half of the cases.
No takes yet. Share an insight, caveat, or question.
Kneizeh et al. (2026) conducted a meta-analysis in Arrhythmic mitral valve prolapse (n=163). Implantable cardioverter-defibrillator (ICD) for secondary prevention was evaluated on Incidence of appropriate ICD therapies (95% CI 5.0-10.6). Patients with arrhythmic mitral valve prolapse and an ICD for secondary prevention had a pooled incidence of appropriate ICD therapies of 7.8 per person-year (95% CI: 5.0-10.6).
Synapse has enriched 10 related papers. Consider them for comparative context: