Key result
Implantation for VT predicted any appropriate ICD therapy (HR 1.45; 95% CI 1.05-2.01; P=0.03) in secondary prevention patients, but no useful predictors for life-threatening arrhythmias were found.
Cohort (n=357)
Hazard Ratio: 1.45 (95% CI 1.05–2.01)
p-value: p=0.03
The rate of appropriate ICD therapies in secondary prevention is high (65% at 10 years), but useful predictors for life-threatening arrhythmias remain elusive.
VT indication was associated with more appropriate therapies in secondary prevention ICDs; leaves open reliable predictors of life-threatening arrhythmias.
AIMS: Incidence of implantable cardioverter-defibrillator (ICD) therapy in secondary prevention has been assessed in randomized trials and registries. However, results are considerably limited by short follow-up and hazy definition of treated arrhythmias. This study aimed to determine appropriate ICD therapy and to define predictors based on registry patients followed for up to 20 years. METHODS AND RESULTS: All patients with a secondary prevention indication and ischaemic or dilated cardiomyopathy were identified. Arrhythmic endpoints were appropriate ICD therapies for any ventricular tachycardia (VT) >175 b.p.m. and appropriate ICD therapies in the ventricular fibrillation (VF) zone of >220 b.p.m. (potentially life-threatening). Predictors were determined by analysing 19 baseline characteristics. We included 357 patients, age 65 ± 11 years, predominantly male (89%) with ischaemic cardiomyopathy (83%). During follow-up of 82 ± 53 months, 156 (44%) patients died and 208 received any form of ICD therapies (59%), 71 of them (34%) in the VF zone. Forty-four patients (28%) died without experiencing any form of appropriate ICD therapy. Cumulative incidence of any form of ICD therapy at 10 years was 65%. Predictors for any form of ICD therapy were implantation for VT and age [VT: hazard ratio (HR) 1.45, 95% confidence interval (95% CI) 1.05-2.01, P = 0.03; age (per year): HR 1.02, 95% CI 1.01-1.04, P = 0.001]. For therapy in the VF zone, univariate analysis determined male gender (29 vs. 5%, P = 0.01) as predictor. CONCLUSION: The rate of appropriate ICD therapies in secondary prevention is high. No useful predictors for them, especially not for life-threatening arrhythmias could be identified.
No takes yet. Share an insight, caveat, or question.
Schaer et al. (2015) conducted a cohort in Secondary prevention implantable cardioverter-defibrillator indication (n=357). Implantation for ventricular tachycardia (VT) was evaluated on Any form of appropriate ICD therapy (HR 1.45, 95% CI 1.05-2.01, p=0.03). Implantation for VT predicted any appropriate ICD therapy (HR 1.45; 95% CI 1.05-2.01; P=0.03) in secondary prevention patients, but no useful predictors for life-threatening arrhythmias were found.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: