Key result
2% alcoholic chlorhexidine fails to reduce device-related infections versus alcoholic povidone-iodine.
Why the study?
Does 2% alcoholic chlorhexidine reduce device-related infections compared to alcoholic povidone-iodine in patients undergoing cardiac implantable electronic device procedures?
RCT (n=2,272)
Open-label
1:1 centrally using an interactive web-response system, stratified by center
Yes
Does 2% alcoholic chlorhexidine reduce device-related infections compared to alcoholic povidone-iodine in patients undergoing cardiac implantable electronic device procedures?
Alcoholic chlorhexidine did not significantly reduce device-related infections compared to alcoholic povidone-iodine in patients undergoing cardiac implantable electronic device implantation.
Answers are grounded in this paper and cite their sources.
No reduction in device infections with chlorhexidine; leaves open optimal antiseptic choice for CIED implantation.
Background Cardiac resynchronization therapy (CRT) improves heart failure outcomes and reduces morbidity and mortality but carries the highest infection risk among cardiac implantable electronic devices. Studies on surgical-site infections show conflicting results regarding the use of alcohol-based povidone-iodine vs. chlorhexidine for skin antisepsis, especially as CRT implantation remains insufficiently studied. Methods In this randomized, multicenter, open-label trial with blinded outcome adjudication, patients undergoing CRT (implantation, upgrade, or replacement) pacemaker, or defibrillator implantation were assigned 1:1 to receive skin antisepsis with either 2% alcoholic chlorhexidine or alcoholic povidone-iodine. Randomization was conducted centrally using an interactive web-response system, with stratification according to trial center. The primary outcome was local or systemic infection related to the device over a 24-month follow-up period. The secondary outcomes were major cardiovascular events and non-infectious side effects. Results From April 2013 to December 2018, 2272 patients were randomized to chlorhexidine (n=1143) or povidone-iodine group (n=1129). Median age was 72 years; 75.1% were men. Device-related infections occurred in 2.9% of the chlorhexidine group and 3.9% of the povidone-iodine group (adjusted subhazard ratio, 0.75; 95% CI, 0.48 to 1.20; P=0.23). Major cardiovascular events occurred in 31.5% and 31.3% of patients, respectively (subhazard ratio, 1.01; 95% CI, 0.87 to 1.17). Non-infectious local side effects occurred in 12.9% vs. 13.3%. Conclusions The study did not demonstrate a significant reduction in infection rates with alcoholic chlorhexidine compared to alcoholic povidone-iodine in patients undergoing cardiac resynchronization device implantation despite a 25% relative risk reduction observed with chlorhexidine. Both antiseptics showed similar rates of major infectious and non-infectious events. Further research is needed to optimize infection prevention strategies in this population.
No takes yet. Share an insight, caveat, or question.
Costa et al. (2026) conducted an RCT in Cardiac implantable electronic device implantation (n=2,272). Alcoholic chlorhexidine vs. Alcoholic povidone-iodine was evaluated on Local or systemic infection related to the device (subhazard ratio 0.75, 95% CI 0.48 to 1.20, p=0.23). Skin antisepsis with 2% alcoholic chlorhexidine did not reduce device-related infections compared to alcoholic povidone-iodine.