Key result
PEAR two-step workflow with balloon-in-basket PFA achieves 100% acute PVI with minimal hemolysis.
Why the study?
Pulsed field ablation is a novel non-thermal energy source for AF ablation, but the feasibility, efficiency, safety, and hemolysis profile of a structured two-step balloon-in-basket workflow remained to be evaluated.
Does the PEAR workflow using a balloon-in-basket PFA catheter achieve efficient and safe pulmonary vein isolation in patients undergoing first-time AF ablation?
Observational (n=50)
Does the PEAR workflow using a balloon-in-basket PFA catheter achieve efficient and safe pulmonary vein isolation in patients undergoing first-time AF ablation?
Answers are grounded in this paper and cite their sources.
The PEAR two-step workflow using a balloon-in-basket PFA catheter achieves 100% acute pulmonary vein isolation efficiently and safely with minimal hemolysis.
Background Pulsed field ablation (PFA) is a novel non-thermal energy source for atrial fibrillation (AF) ablation. We evaluated a structured two-step Pulmonary vein and slEeve Ablation stRategy (PEAR workflow) using a balloon-in-basket PFA catheter with integrated occlusion guidance and mapping. Purpose To assess the feasibility, procedural efficiency, safety, and hemolysis profile of the PEAR workflow in consecutive AF patients. Methods Fifty consecutive patients undergoing first-time AF ablation were treated under deep sedation using the balloon-in-basket PFA catheter. The PEAR workflow comprised (1) four occlusion-guided antral PFA applications with full balloon inflation, followed by (2) two distal, partially deflated ("pear-shaped") applications targeting the PV sleeves. Procedural, efficacy, and laboratory parameters were analyzed. Results All 199 pulmonary veins were successfully isolated (100% acute PVI). Median procedure and fluoroscopy times were 50 min (IQR 41–60) and 7.2 min (IQR 5.8–11.4), respectively, with no major complications and two transient phrenic nerve palsies. Post-procedural laboratory testing showed minimal hemolysis: creatinine (pre-ablation 0.98 ± 0.25 mg/dl vs. post-ablation 0.98 ± 0.24 mg/dl, p=0.272), haptoglobin (pre: 110 ± 33 g/l vs. post: 105 ± 34 g/l post, p=0.061) and hemoglobin values (pre: 13 ± 1.5 g/dl vs. post: 13 ± 1.4 g/dl, p=0.377), before and one day after PFA did not differ. Conclusion The PEAR two-step workflow enables rapid, efficient, and safe PVI with minimal hemolysis and preserved renal function. Occlusion-guided positioning and sleeve-targeted ablation provide a reproducible, operator-friendly approach supporting streamlined clinical adoption.
No takes yet. Share an insight, caveat, or question.
Urbani et al. (2026) conducted an observational in atrial fibrillation (n=50). PEAR workflow using a balloon-in-basket PFA catheter was evaluated on acute pulmonary vein isolation. The PEAR two-step workflow using a balloon-in-basket pulsed field ablation catheter achieved 100% acute pulmonary vein isolation in 50 patients with minimal hemolysis.