Key result
Closed-loop stimulation fails to improve exercise duration over VVIR pacing in AF with chronotropic incompetence.
Why the study?
Data on closed-loop stimulation (CLS) rate-adaptive pacing in patients with permanent AF, chronotropic incompetence, and left bundle branch area pacing (LBBAP) are limited.
Does closed-loop stimulation (CLS) pacing improve exercise capacity and physiological responses compared to VVIR pacing in patients with permanent AF, chronotropic incompetence, and LBBAP?
RCT (n=21)
Single-blind
Does closed-loop stimulation (CLS) pacing improve exercise capacity and physiological responses compared to VVIR pacing in patients with permanent AF, chronotropic incompetence, and LBBAP?
Answers are grounded in this paper and cite their sources.
In patients with permanent AF and chronotropic incompetence undergoing LBBAP, CLS pacing did not significantly improve exercise capacity or handgrip performance compared to standard VVIR pacing.
Background Chronotropic incompetence (CI) is frequent in patients with permanent atrial fibrillation (AF) treated with ventricular pacing and is associated with exercise intolerance and reduced quality of life. Left bundle branch area pacing (LBBAP) restores physiological ventricular activation, while closed-loop stimulation (CLS) adapts pacing rate to contractility changes, potentially providing a more physiological rate response than standard VVIR mode. However, data on CLS in LBBAP patients with CI is limited. Purpose To compare CLS and conventional VVIR pacing in patients with permanent AF and CI treated with LBBAP. Methods This prospective, single-blind, cross-over study included patients with permanent AF, CI, and >50% ventricular pacing burden after LBBAP implantation. During the first phase, patients were evaluated in CLS mode using a standardized protocol: handgrip test (5 min at 30% maximal strength), mental stress test (Paced Auditory Serial Addition Test – PASAT), and treadmill exercise test (modified Bruce protocol), all under continuous 12-lead ECG monitoring. Between tests, ≥5 min rest was allowed for heart rate recovery. Device follow-up was performed at each visit. After one month, the pacing mode was switched to VVIR, and all assessments were repeated. The quality of life was assessed using the EQ-5D-5L questionnaire, and patients were asked to indicate their preferred mode. Results Twenty-one patients completed both phases. Exercise duration (4.9 ± 6 vs 3.7 ± 4 min, p = 0.19), METs (3.8 ± 3 vs 2.6 ± 3, p = 0.11), ΔHR (33.9 ± 12 vs 34 ± 15 bpm, p = 0.94), and Borg scale (15 ± 2 vs 15 ± 2, p = 0.16) did not differ between CLS and VVIR. CLS induced a higher BP response during PASAT (ΔSBP 5 ± 9 vs 4 ± 5 mmHg, p = 0.03) but a lower proportion of correct answers (36.7 ± 23 vs 61.4 ± 15%, p < 0.001). Handgrip ΔHR tended to be higher with CLS (7 ± 20 vs 0 ± 5 bpm, p = 0.10). Device parameters were comparable except for higher ventricular pacing percentage (94 ± 16 vs 87 ± 40%, p = 0.03) and impedance (354 vs 340 Ω, p = 0.001) in CLS. EQ-5D-5L scores were similar: Visual Analogue Scale (VAS) 69.4 (24) vs 64.1 (27), p = 0.83; index 0.97 (0,126) vs 0.94 (0,078), p = 0.08. Conclusion In patients with permanent AF, CI, and LBBAP, CLS did not significantly improve exercise capacity or handgrip performance compared with VVIR pacing. CLS elicited higher BP responses but lower cognitive performance during mental stress, with no relevant differences in device parameters. Larger studies are warranted to define its clinical role.
No takes yet. Share an insight, caveat, or question.
Wrobel et al. (2026) conducted an RCT in Permanent atrial fibrillation and chronotropic incompetence (n=21). Closed-loop stimulation (CLS) pacing vs. Conventional VVIR pacing was evaluated on Exercise duration (minutes) (p=0.19). Closed-loop stimulation pacing did not improve exercise duration compared with VVIR pacing in patients with permanent AF and chronotropic incompetence.
Synapse has enriched 10 related papers. Consider them for comparative context: