Key result
Closed-loop stimulation linked to ~69% lower AF/AT risk versus fixed-rate pacing.
Why the study?
The effectiveness of rate-modulated pacing for atrial fibrillation suppression is controversial, prompting investigation into whether closed-loop stimulation reduces atrial tachyarrhythmia burden in patients with sinus node dysfunction and paroxysmal atrial fibrillation.
Does closed-loop stimulation reduce atrial tachyarrhythmia burden in patients with sinus node dysfunction and a history of atrial fibrillation?
Cohort (n=146)
Does closed-loop stimulation reduce atrial tachyarrhythmia burden in patients with sinus node dysfunction and a history of atrial fibrillation?
Closed-loop stimulation pacing is associated with a significantly lower atrial tachyarrhythmia burden compared to fixed-rate or non-CLS rate-modulated pacing in patients with sinus node dysfunction and prior AF.
Answers are grounded in this paper and cite their sources.
CLS may lower AF burden in paced patients; leaves open need for RCTs before practice change.
INTRODUCTION: The effectiveness of rate-modulated pacing for the suppression of atrial fibrillation (AF) is controversial. Closed-loop stimulation (CLS) is a heart rate modulation technique based on the contractility of the right ventricle estimated by sensing myocardial impedance, and CLS can still adapt to the heart rate in conditions where there are no significant changes in acceleration or ventilation, such as emotional stress. We elucidated the association between CLS and atrial tachyarrhythmia (AT) burden in patients with sinus node dysfunction and paroxysmal AF history before pacemaker implantation. METHODS AND RESULTS: We retrospectively reviewed all consecutive patients who underwent pacemaker implantation for sinus node dysfunction with an AF history before implantation. Overall, 146 patients were analyzed, with fixed-rate pacing (FP) in 82, CLS in 31, and non-CLS rate modulation in 33 patients. The AF/AT episodes were detected in 98 patients during a 12-month period. The median AF/AT burden was 1.6% (interquartile: 0.0%, 11.0%) in FP; 0% (0.0%, 2.5%) in CLS, and 1.0% (0.1%, 9.3%) in non-CLS. The AF/AT burden was significantly lower for CLS than for FP and non-CLS rate modulation (P < .01 and P = .04, respectively). CLS was associated with lower risks of AF/AT occurrence (hazard ratio [HR], 0.31; P = .02) and AF/AT burden more than 5% (HR, 0.28; P = .05), even after adjusting for potential confounders. This association was independent of the percentage of atrial pacing. CONCLUSION: CLS was associated with lower AF/AT burden after pacemaker implantation in patients with sinus node dysfunction and AF history.
No takes yet. Share an insight, caveat, or question.
Ikeda et al. (2020) conducted a cohort in Sinus node dysfunction and paroxysmal atrial fibrillation history (n=146). Closed-loop stimulation (CLS) vs. Fixed-rate pacing (FP) and non-CLS rate modulation was evaluated on Atrial fibrillation/atrial tachyarrhythmia (AF/AT) burden (p=<0.01). Closed-loop stimulation was associated with a lower median AF/AT burden compared to fixed-rate pacing and a lower risk of AF/AT occurrence.
Synapse has enriched 10 related papers. Consider them for comparative context: