Key result
Single-shot PVI is associated with similar durable isolation to point-by-point ablation but higher right-sided reconnection.
Why the study?
Single-shot devices and point-by-point radiofrequency ablation create lesions with distinct biophysical properties, raising the question of whether they produce different PV reconnection patterns in recurrent AF.
Does initial single-shot PVI compared to point-by-point ablation result in different pulmonary vein reconnection patterns in patients with recurrent atrial fibrillation?
Observational (n=105)
No
Does initial single-shot PVI compared to point-by-point ablation result in different pulmonary vein reconnection patterns in patients with recurrent atrial fibrillation?
Initial single-shot PVI is associated with a higher rate of right-sided pulmonary vein reconnections compared to point-by-point ablation in patients requiring repeat procedures for recurrent atrial fibrillation.
Answers are grounded in this paper and cite their sources.
May guide right-vein mapping in redo AF procedures after single-shot PVI; leaves open effects on overall isolation durability.
Background/Introduction Pulmonary vein isolation (PVI) is the cornerstone of atrial fibrillation (AF) ablation. Even after successful PVI procedures, AF can recure. Nevertheless, these recurrences are frequently driven by PV reconnections. Single-shot devices and point-by-point radiofrequency ablation create lesions with distinct biophysical properties, raising the question of whether they are associated with different PV reconnection patterns. Aims To describe PV reconnection patterns in patients undergoing repeat electrophysiological procedures for recurrent AF and to compare these patterns between initial point-by-point ablation and single-shot PVI. Methods We retrospectively analyzed 105 consecutive patients who underwent a repeat electrophysiological procedure in a single center study between 2021 and 2023 due to recurrent AF after PVI. Based on the initial ablation strategy, patients were divided into two groups: PP (n=65) versus SS (n=40). During the repeat procedures, all PVs were systematically remapped and assessed for electrical reconnections. The number of reconnected PVs per patient, the distribution of reconnection across PVs, and procedural characteristics were compared between groups using standard statistical methods. Results There was no significant difference in the proportion of patients without PV reconnection between the two groups (PP: 19/65, 29% vs. SS: 7/40, 18%; p=0.18). When all veins were considered, 40% in the PP group and 47% in the SS group showed reconnection (PP: 105/260, 40% vs. SS: 75/160, 47%; p=0.30). In contrast, right-sided PV reconnection was significantly more frequent following initial SS ablation (PP: 37/65, 57% vs. SS: 31/40, 78%; p=0.03). No significant difference was observed for left-sided PVs (PP: 24/65, 37% vs. SS: 18/40, 45.0%; p=0.38). Procedural duration, fluoroscopy time, and radiation dose during the repeat procedures did not differ significantly between the two groups. Conclusions Approximately one in four patients undergoing repeat procedures after PVI showed no PV reconnection, suggesting durable isolation and non-PV drivers in the initiation of AF. Among patients with reconnection, initial ablation with SS devices was associated with a higher number of right-sided PV reconnection.
No takes yet. Share an insight, caveat, or question.
Nemeth et al. (2026) conducted an observational in recurrent atrial fibrillation (n=105). Initial single-shot ablation vs. Initial point-by-point ablation was evaluated on Proportion of patients without pulmonary vein reconnection (p=0.18). Initial ablation with single-shot devices showed no significant difference in overall durable isolation compared to point-by-point ablation, but had higher right-sided reconnection.
Synapse has enriched 10 related papers. Consider them for comparative context: