Why the study?
The efficacy and safety of monopolar biphasic focal pulsed field ablation in close proximity to the atrioventricular node remain unknown.
Does monopolar biphasic focal pulsed field ablation directly at the AV junction or from within the non-coronary cusp safely and effectively alter AV conduction or terminate parahisian arrhythmias?
Does monopolar biphasic focal pulsed field ablation directly at the AV junction or from within the non-coronary cusp safely and effectively alter AV conduction or terminate parahisian arrhythmias?
F-PFA directly at the AV junction effectively creates complete AV block, while application from the NCC may safely treat parahisian arrhythmias without causing permanent AV node damage.
Answers are grounded in this paper and cite their sources.
Requires human validation before adoption; extends preclinical data on focal PFA for AV nodal and parahisian targets.
Background The efficacy and safety of monopolar biphasic focal pulsed field ablation (F-PFA) in close proximity to the atrioventricular (AV) node remain unknown. Objective To describe the effect of direct or indirect F-PFA application at the AV junction. Methods In pigs, F-PFA (Centauri) was applied directly at the AV junction (n=3) and indirectly from within the aortic non-coronary cusp (NCC) (n=5), followed by macroscopic gross and histological analysis. In five patients planned for a pace-and-ablate strategy, F-PFA was applied at the AV junction. In one patient with recurrent parahisian atrial tachycardia (AT) and previously failed ablation, F-PFA was applied from within the NCC. Results In pigs, direct F-PFA applications at the AV junction were associated with junctional beats and resulted in complete AV block after 2-3 F-PFA applications. Tissue histology revealed a lesion depth of approximately 8mm with minor haemorrhage and leukocyte infiltration. F-PFA from within the NCC resulted in a transient increase in the AV node’s Wenckebach cycle length and one pig had transient AV block, which recovered within 10 min. In five patients undergoing pace-and-ablate strategy, F-PFA applications at the AV junction resulted in sustained AV block. In one patient, application of F-PFA from within the NCC resulted in termination and non-inducibility of a recurrent incessant parahisian AT without AV block. There were no immediate or long-term complications. Conclusion F-PFA directly at the AV junction results in non-reversible AV block. F-PFA from within the NCC may represent a promising strategy for treating parahisian arrhythmias while preserving AV conduction.