Why the study?
The efficacy and safety of monopolar biphasic focal pulsed field ablation in close proximity to the atrioventricular node remain unknown.
Does focal pulsed field ablation directly at the AV junction or from within the noncoronary cusp safely and effectively induce AV block or treat para-Hisian arrhythmias?
Does focal pulsed field ablation directly at the AV junction or from within the noncoronary cusp safely and effectively induce AV block or treat para-Hisian arrhythmias?
Focal pulsed field ablation directly at the AV junction effectively creates nonreversible AV block, while application from within the noncoronary cusp may treat para-Hisian arrhythmias while preserving AV conduction.
Answers are grounded in this paper and cite their sources.
F-PFA near the AV junction or NCC is hypothesis-generating; should not yet alter clinical ablation practice.
BACKGROUND: The efficacy and safety of monopolar biphasic focal pulsed field ablation (F-PFA) in close proximity to the atrioventricular (AV) node remain unknown. OBJECTIVE: This study aimed to describe the effect of direct or indirect F-PFA application at the AV junction. METHODS: In pigs, F-PFA (Centauri, CardioFocus) was applied directly at the AV junction (n = 3) and indirectly from within the aortic noncoronary cusp (NCC) (n = 5), followed by macroscopic gross and histologic analysis. In 5 patients planned for a pace-and-ablate strategy, F-PFA was applied at the AV junction. In 1 patient with recurrent para-Hisian atrial tachycardia and previously failed ablation, F-PFA was applied from within the NCC. RESULTS: In pigs, direct F-PFA applications at the AV junction were associated with junctional beats and resulted in complete AV block after 2-3 F-PFA applications. Tissue histology revealed a lesion depth of approximately 8 mm with minor hemorrhage and leukocyte infiltration. F-PFA from within the NCC resulted in a transient increase in the AV node's Wenckebach cycle length and 1 pig had transient AV block, which recovered within 10 minutes. In 5 patients undergoing pace-and-ablate strategy, F-PFA applications at the AV junction resulted in sustained AV block. In 1 patient, application of F-PFA from within the NCC resulted in termination and noninducibility of a recurrent incessant para-Hisian atrial tachycardia without AV block. There were no immediate or long-term complications. CONCLUSION: F-PFA directly at the AV junction results in nonreversible AV block. F-PFA from within the NCC may represent a promising strategy for treating para-Hisian arrhythmias while preserving AV conduction.
No takes yet. Share an insight, caveat, or question.
Liu et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: