Key result
An individualized treadmill exercise test simulating marathon competition successfully provoked supraventricular tachycardia of 230 bpm, validating the athlete's sports heart rate monitor readings.
Case Report (n=1)
No
This case highlights the diagnostic utility of sports heart rate monitors and competition-simulating exercise tests in diagnosing elusive exercise-induced arrhythmias.
A 36-year-old professional marathon runner reported sudden irregular palpitations occurring during competitions, with heart rates (HR) up to 230 bpm recorded on a sports HR monitor (HRM) over 4 years. These episodes subsided upon the cessation of exercise. Electrocardiograms, echocardiography, and cardiac magnetic resonance imaging results were borderline for athlete's heart. Because an electrophysiology study and standard exercise tests provoked no arrhythmia, doctors suspected Munchausen syndrome. Ultimately, an exercise test that simulated the physical effort of a competition provoked tachyarrhythmia consistent with the HRM readings. This case demonstrates the diagnostic difficulties related to exercise-induced arrhythmia and the diagnostic usefulness of sports HRMs.
No takes yet. Share an insight, caveat, or question.
Gajda et al. (2023) conducted a case report in Exercise-induced arrhythmia (n=1). Individualized treadmill exercise test simulating competition effort was evaluated on Provocation of tachyarrhythmia consistent with sports heart rate monitor readings. An individualized treadmill exercise test simulating marathon competition successfully provoked supraventricular tachycardia of 230 bpm, validating the athlete's sports heart rate monitor readings.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: