Key result
Postural change to a supine position decreased carotid-femoral pulse wave velocity, highlighting significant anatomical and individual variability in BP/PTT calibration.
Cross-Sectional (n=113)
There is significant anatomical site and between-individual variability in the calibration term for cuffless blood pressure estimation from pulse transit time, highlighting the need for individualized calibration methods.
Answers are grounded in this paper and cite their sources.
cfPWV decreases supine; hypothesis-generating for posture effects on vascular stiffness assessment.
Objective: Measuring arterial pulse transit time (PTT) to estimate blood pressure (BP) without conventional brachial cuff-based measurement is not new, but is a focus of current wearable technologies research. Much research pertains to efficient, accurate sensing of arteryrelated waveforms, yet the relationship between PTT and BP receives less attention despite being key for accurate BP estimation. This study investigated BP/PTT calibration by quantifying anatomical site variability (n = 10, 3 female, age 30 ± 9 years) and individual variability (n = 103, 50 female, age 53 ± 22 years). Methods: BP and pulse wave velocity (PWV) were measured in both seated and supine. Carotid-femoral PWV (cfPWV), carotid-radial PWV (crPWV), and carotid-finger-volume PWV (cvPWV) were measured with the wrist and hand positioned at the level of the upper thigh to achieve the same hydrostatic pressure effect across all measurements. Results:The postural change invoked a small (4 ± 7 mmHg) change in brachial diastolic BP with an additional 27 ± 2 mmHg change in hydrostatic pressure. cfPWV decreased in the supine position (-1.75 ± 0.17 m·s-1, p <; 0.001), but crPWV and cvPWV were more variable. The calibration term (ΔBP/ΔPWV) across the sample population varied from 6.6 to 98.3 mmHg·s·m-1(mean 22 ± 14 mmHg·s·m-1) and was correlated with age, heart rate, diastolic and pulse pressure, and weight. These variables did not explain the majority of the variability (R2 = 0.248). Conclusion: There is anatomical site and betweenindividual variability in the calibration term for BP estimation from PTT. Significance: Using and accurately calculating hydrostatic changes in BP within the individual may be one method to increase the accuracy of this calibration term.
No takes yet. Share an insight, caveat, or question.
Butlin et al. (2018) reported a cross-sectional. Postural change (seated to supine) vs. Seated position was evaluated on Change in carotid-femoral pulse wave velocity (cfPWV) (MD -1.75, p=<0.001). Postural change to a supine position decreased carotid-femoral pulse wave velocity, highlighting significant anatomical and individual variability in BP/PTT calibration.
Synapse has enriched 10 related papers. Consider them for comparative context: