Compares hemostatic efficacy of oxidized regenerated cellulose and fibrin glue in rats, indicating treatment effectiveness for liver hemorrhage.
The objective of this study is to compare the hemostatic efficacy of oxidised regenerated cellulose powder (Surgicel ® Powder) and fibrin glue (Tisseel ® ) in a rat model of liver parenchymal haemorrhage, and to evaluate their effects on tissue healing. Preoperative haemoglobin and haematocrit values were comparable among the groups ( p > 0.05). At 24 h, postoperative haemoglobin and haematocrit values differed significantly among the three groups ( p = 0.045 and p = 0.042, respectively), with lower values in the saline-compression control group and relatively preserved values in the Surgicel ® Powder and Tisseel ® groups. However, no statistically significant difference was identified between the two active treatment groups. Histopathological evaluation revealed no statistically significant between-group differences in necrosis, inflammation, fibrosis, haemorrhage, or granulation tissue formation ( p > 0.05).
No takes yet. Share an insight, caveat, or question.
Acar et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: