Key result
Novel precordial lead ECG improves right ventricular enlargement detection, led by V4 R/S ratio.
Why the study?
The reliability of precordial leads for detecting right ventricular enlargement in dogs needed evaluation.
Does the assessment of precordial leads improve the diagnostic accuracy of ECG for detecting right ventricular enlargement in dogs?
Observational (n=84)
Yes
Does the assessment of precordial leads improve the diagnostic accuracy of ECG for detecting right ventricular enlargement in dogs?
Assessment of the R/S ratio in V4 and V5 and S wave amplitude in V6 increases the diagnostic accuracy of ECG in distinguishing between dogs with RVE and healthy dogs.
Answers are grounded in this paper and cite their sources.
May enhance ECG detection of canine right ventricular enlargement; leaves open need for prospective validation before clinical adoption.
The purpose of this study was to evaluate the reliability of precordial leads for the detection of right ventricular enlargement (RVE) in dogs. This was a prospective observational study. The RVE was defined by echocardiography. The amplitude (mV) of the Q, R, and S waves, the R/S ratio, and the mean electrical axis (MEA) of the QRS complex were assessed on the 12-lead ECG. The ROC curve and the Youden index yielded the best cutoffs for RVE detection. An area under the curve (AUC) > 0.7 defined suitable diagnostic accuracy. A total of 84 dogs, 27 with RVE and 57 healthy controls, were enrolled. Q wave amplitude in aVR (cutoff > 0.10 mV; AUC = 0.727), R/S ratio in V4 (cutoff < 1.15; AUC = 0.842), R/S ratio in V5 (cutoff < 1.95; AUC = 0.839) and S wave amplitude in V6 (cutoff > 0.70 mV; AUC = 0.703) showed suitable diagnostic accuracy in detecting RVE. Among dogs with RVE, only 9/27 (33%) presented a right shift of MEA. Differently, 19/27 (70%) showed at least one of the identified precordial lead criteria. Assessment of the R/S ratio in V4 and V5 and S wave amplitude in V6 increases the diagnostic accuracy of ECG in distinguishing between dogs with RVE and healthy dogs.
No takes yet. Share an insight, caveat, or question.
Grosso et al. (2022) conducted an observational in Right ventricular enlargement (n=84). 12-lead ECG with a novel precordial lead system vs. Standard 6-lead ECG was evaluated on Diagnostic accuracy (Area Under the Curve) for detecting right ventricular enlargement (AUC 0.842). A novel precordial lead system increased the diagnostic accuracy of 12-lead ECG for detecting right ventricular enlargement in dogs, with the R/S ratio in V4 demonstrating the highest accuracy.