Key result
Carotid artery VTI is feasible in ~94% of unsedated dogs and correlates with aortic VTI.
Why the study?
Common carotid artery velocity-time integral (CCA-VTI) may offer an accessible peripheral measurement for hemodynamic assessment, but its relationship with aortic velocity-time integral (Ao-VTI) in dogs remains unclear.
Does common carotid artery velocity–time integral correlate and agree with aortic velocity–time integral in unsedated client-owned dogs?
Observational (n=51)
Does common carotid artery velocity–time integral correlate and agree with aortic velocity–time integral in unsedated client-owned dogs?
In unsedated dogs, common carotid artery velocity–time integral is feasible to acquire and positively correlates with aortic velocity–time integral, though individual measurement variability prevents them from being used interchangeably.
Answers are grounded in this paper and cite their sources.
Carotid VTI appears feasible in unsedated dogs; leaves open validation and interchangeability with aortic VTI before clinical use.
Common carotid artery velocity–time integral (CCA-VTI) may offer an accessible peripheral measurement for hemodynamic assessment, but its relationship with aortic velocity–time integral (Ao-VTI) in dogs remains unclear. This prospective observational pilot study evaluated their association, agreement, technical feasibility, and acquisition times in 51 unsedated client-owned dogs. A single investigator sequentially obtained both measurements using pulsed-wave Doppler, averaging three consecutive cardiac cycles. No preload-modifying intervention was performed. Data were evaluated using Pearson correlation, linear regression, Bland–Altman analysis, and the Wilcoxon matched-pairs signed-rank test. Technically adequate CCA-VTI measurements were obtained in 48 dogs (94.1%), which were included in the paired analyses. CCA-VTI was positively correlated with Ao-VTI (r = 0.7021, p < 0.001; R2 = 0.4929). There was no statistically significant difference in acquisition time between CCA-VTI and Ao-VTI. CCA-VTI acquisition was feasible in most unsedated dogs and showed a significant positive association with Ao-VTI. However, variability between individual measurements precludes assuming interchangeability. Further validation against independent blood-flow measurements and during controlled preload interventions is needed before clinical use for systemic flow estimation or fluid-responsiveness assessment.
No takes yet. Share an insight, caveat, or question.
Choo et al. (2026) conducted an observational in Hemodynamic assessment in unsedated dogs (n=51). Common carotid artery velocity-time integral (CCA-VTI) measurement vs. Aortic velocity-time integral (Ao-VTI) measurement was evaluated on Correlation, agreement, technical feasibility, and acquisition time between CCA-VTI and Ao-VTI (r = 0.7021, R2 = 0.4929, p=< 0.001). Common carotid artery VTI was feasible in 94.1% of unsedated dogs and positively correlated with aortic VTI.
Synapse has enriched 10 related papers. Consider them for comparative context: