Key result
Systolic carotid flow correlates strongly with cardiac output, supporting its potential as a surrogate.
Why the study?
Does common carotid artery blood flow correlate with cardiac output in healthy volunteers during hemodynamic maneuvers?
Observational (n=20)
Does common carotid artery blood flow correlate with cardiac output in healthy volunteers during hemodynamic maneuvers?
Effect estimate: Spearman correlation 0.67
p-value: p=< 0.001
Systolic carotid flow and corrected flow time measured by ultrasound correlate significantly with cardiac output during hemodynamic maneuvers, suggesting potential as a non-invasive surrogate.
Hypothesis-generating for carotid flow as a noninvasive cardiac output surrogate; leaves open validation in critically ill patients.
Objective: Evaluation of common carotid artery (CCA) blood flow can provide valuable information regarding the hemodynamic status of a patient. Utilizing ultrasound, we aimed to evaluate the correlation between cardiac output and different hemodynamic parameters in the CCA, namely systolic carotid flow (SCF), corrected flow time (CFT), and total carotid flow (TCF). Methods: We studied a pilot sample of 20 healthy volunteers. Hemodynamic parameters were collected in the right CCA and the heart at rest (baseline), 1-leg compression, 2-leg compression, and passive leg raise. Nonparametric Spearman correlation was calculated using STATA 13 software. Results: This study demonstrated the feasibility and safety of the leg compression testing as a hemodynamic maneuver to simulate volume depletion status. We demonstrated a direct correlation between cardiac output and SCF of 0.67 with a P value < 0.001. Interestingly, TCF calculated based on volume–time integral (VTI) in the carotid artery showed positive correlation of only 0.41, with P < 0.06, and it did not reach statistical significance. We also found a positive correlation between CFT and cardiac output at baseline 0.57, with P < 0.001. Conclusion: Variations in cardiac preload and the subsequent alterations in cardiac output were directly translatable into variations in the carotid blood flow. This supports the potential for using carotid flow as a surrogate for cardiac output. The most promising parameters were SCF, CFT, and carotid systolic VTI. Further work is needed to validate these correlations and utilize these acquired carotid parameters to guide fluid management and predict fluid responsiveness.
No takes yet. Share an insight, caveat, or question.
Sidor et al. (2018) conducted an observational in Hemodynamically stable participants (n=20). Ultrasound evaluation of common carotid artery blood flow during hemodynamic maneuvers was evaluated on Correlation between cardiac output and systolic carotid flow (SCF) (Spearman correlation 0.67, p=< 0.001). Systolic carotid flow directly correlated with cardiac output (Spearman correlation 0.67, P<0.001) during hemodynamic maneuvers, supporting its potential as a surrogate for cardiac output.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: