Key result
Clopidogrel responders had a significantly lower incidence of periprocedural thromboembolic events compared to hypo-responders during neurointervention (RR 0.32).
Why the study?
The efficacy of VerifyNow P2Y12 reaction unit (PRU) remains controversial in neurointervention, and the safety of modified DAPT or TAPT for clopidogrel hypo-responders required evaluation.
Does PRU assessment predict periprocedural thromboembolic and hemorrhagic events, and does modified DAPT/TAPT reduce these events in clopidogrel hypo-responders undergoing neurointervention?
Meta-Analysis (n=1,826)
Does PRU assessment predict periprocedural thromboembolic and hemorrhagic events, and does modified DAPT/TAPT reduce these events in clopidogrel hypo-responders undergoing neurointervention?
Relative Risk: 0.32 (95% CI 0.17–0.61)
p-value: p=<0.001
PRU is a useful predictor of periprocedural thromboembolic and hemorrhagic events in neurointervention, but modifying antiplatelet therapy for clopidogrel hypo-responders did not significantly reduce thromboembolic events.
Clopidogrel responders show markedly lower peri-procedural TE risk; confirms P2Y12 reactivity as predictor and supports testing before neurointerventions.
The efficacy of P2Y12 reaction unit (PRU) of VerifyNow still remains as a controversial issue in neurointervention. So we investigated the usefulness of PRU of VerifyNow to predict the peri-procedural thromboembolic events (TE) and hemorrhagic events (HE). And we evaluated the safety of modified dual antiplatelet therapy (DAPT) or triple antiplatelet therapy (TAPT) for clopidogrel hyporesponders. We searched MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials, Web of Science and Scopus on August 19 2018. Data was collected the 1) incidence of TE between clopidogrel responder and clopidogrel hypo-responder, 2) incidence of HE between clopidogrel hyper-responder and clopidogrel responder and hypo-responder, and 3) incidence of TE and HE between modified DAPT or TAPT and standard DAPT in clopidogrel hypo-responder. High cut-off value of PRU was defined as PRU >40% or <220. Fifteen studies were enrolled. Clopidogrel responder showed lower incidence of TE than hypo-responder (risk ratio [RR], 0.32; 95% confidence interval [CI], 0.17-0.61; p<0.001). With the high cut-off value of PRU, clopidogrel responder showed more lower incidence of TE than hypo-responder (RR, 0.11; 95% CI, 0.02-0.45; p=0.002). The incidence of periprocedural HE have higher on clopidogrel hyper-responder than clopidogrel responder and hypo-responder (RR, 4.26; 95% CI, 1.10-16.44; p=0.04; I2=66%). The incidence of periprocedural TE after changing regimen of DAPT for clopidogrel hypo-responder have a tendency to reduce, but there was no significant difference between modified DAPT or TAPT group and standard DAPT group (p>0.05). The incidence of periprocedural HE after changing regimen of DAPT for clopidogrel hypo-responder was no significant difference between modified DAPT or TAPT group and standard DAPT group (p>0.05). PRU is a useful tool as a predictor of peri-procedural TE or HE on neurointervention. PRU has a threshold effect of cut-off value to predict the peri-procedural TE. Modified DAPT or TAPT to prevent TE in clopidogrel hypo-responders could not reduce the incidence of TE. We should investigate the further research about modification of regiment on neurointervention.
No takes yet. Share an insight, caveat, or question.
Kim et al. (2019) conducted a meta-analysis in Neurointervention (stent-assisted coil embolization, extracranial or intracranial stenting) (n=1,826). Clopidogrel responder (inhibition group) vs. Clopidogrel hypo-responder (no-inhibition group) was evaluated on Incidence of periprocedural thromboembolic events (TE) (RR 0.32, 95% CI 0.17-0.61, p=<0.001). Clopidogrel responders had a significantly lower incidence of periprocedural thromboembolic events compared to hypo-responders during neurointervention (RR 0.32).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: