Key result
Tissue Proximity Indication-guided PFA achieves first-pass PVI in 90% of patients.
Why the study?
Although TPI-negative sites contribute to gap formation during pulsed-field ablation with the variable-loop circular catheter, no studies have evaluated the utility of its real-time Tissue Proximity Indication function.
Does an activated TPI function-guided PFA strategy using a variable-loop circular catheter improve the success rate of pulmonary vein isolation in patients undergoing PFA?
Observational (n=60)
Does an activated TPI function-guided PFA strategy using a variable-loop circular catheter improve the success rate of pulmonary vein isolation in patients undergoing PFA?
Activated TPI function-guided PFA with a variable-loop circular catheter yields a high rate of first-pass pulmonary vein isolation and low incidence of residual potentials.
Background The variable‐loop circular catheter (VLCC, VARIPULSE) is a pulsed‐field ablation (PFA) catheter equipped with a Tissue Proximity Indication (TPI) function, which monitors catheter‐tissue contact. Although TPI‐negative sites have been reported to contribute to gap formation, no studies have evaluated the utility of real‐time function. This study assessed the success rate of pulmonary vein isolation (PVI) using the VLCC, incorporating the activated TPI function as the primary setting from the start of the procedure, representing an activated TPI function‐guided ablation approach. Methods Between February 1 and September 3, 2025, 60 consecutive patients underwent PFA using the VLCC. After creating the 3D geometry using CARTOSOUND FAM before ablation, PVI using the VLCC was performed with the activated TPI function. After an initial two‐by‐two PFA set, the catheter orientation was adjusted to target areas without visible TPI‐positive tags. After applying an additional PFA application to ensure a circumferential TPI function‐on tags, a voltage map was created using a multielectrode catheter, and the rate of residual potentials was compared. Results Using an activated TPI function‐guided PFA strategy, a first pass isolation was successfully achieved in 90% of patients (54/60) and in 97.1% of pulmonary veins (231/238). Multielectrode catheter mapping revealed residual antrum potentials in some cases, necessitating additional PFA applications in 3.8% of the pulmonary vein antrum (9/238). Conclusion Activated TPI function‐guided PFA was associated with a low incidence of residual PV potentials, suggesting its potential utility to improve lesion continuity and procedural efficacy.
No takes yet. Share an insight, caveat, or question.
Narita et al. (2026) conducted an observational in Pulmonary vein isolation (n=60). Activated Tissue Proximity Indication (TPI) function-guided pulsed-field ablation was evaluated on First pass isolation. An activated Tissue Proximity Indication function-guided pulsed-field ablation strategy achieved first-pass pulmonary vein isolation in 90% of patients and 97.1% of pulmonary veins.