Key result
The RSL_ANN artificial neural network identified atrial fibrillation in ECGs acquired by portable devices with an AUC of 90.8% (95% CI 88.1-93.5%) in the testing dataset.
Why the study?
AF diagnosis is typically based on hospital or clinical ECG evaluation, creating a need for reliable AF identification using ECGs acquired through portable devices.
Does an artificial neural network using 19 ECG features reliably identify atrial fibrillation in short single-lead ECGs from portable devices?
Does an artificial neural network using 19 ECG features reliably identify atrial fibrillation in short single-lead ECGs from portable devices?
Effect estimate: AUC 90.8% (95% CI 88.1-93.5)
A supervised fully connected artificial neural network demonstrated high accuracy (AUC >90%) for identifying atrial fibrillation from short single-lead ECGs acquired via portable devices.
May support AI-assisted AF screening on portable devices; leaves open prospective validation before clinical adoption.
Atrial fibrillation (AF) is a common cardiac disorder that can cause severe complications. AF diagnosis is typically based on the electrocardiogram (ECG) evaluation in hospitals or in clinical facilities. The aim of the present work is to propose a new artificial neural network for reliable AF identification in ECGs acquired through portable devices. A supervised fully connected artificial neural network (RSL_ANN), receiving 19 ECG features (11 morphological, 4 on F waves and 4 on heart-rate variability (HRV)) in input and discriminating between AF and non-AF classes in output, was created using the repeated structuring and learning (RSL) procedure. RSL_ANN was created and tested on 8028 (training: 4493; validation: 1125; testing: 2410) annotated ECGs belonging to the "AF Classification from a Short Single Lead ECG Recording" database and acquired with the portable KARDIA device by AliveCor. RSL_ANN performance was evaluated in terms of area under the curve (AUC) and confidence intervals (CIs) of the received operating characteristic. RSL_ANN performance was very good and very similar in training, validation and testing datasets. AUC was 91.1% (CI: 89.1-93.0%), 90.2% (CI: 86.2-94.3%) and 90.8% (CI: 88.1-93.5%) for the training, validation and testing datasets, respectively. Thus, RSL_ANN is a promising tool for reliable identification of AF in ECGs acquired by portable devices.
No takes yet. Share an insight, caveat, or question.
Marinucci et al. (2020) studied Atrial fibrillation (n=8,028). RSL_ANN (artificial neural network) was evaluated on Area under the curve (AUC) for AF identification (AUC 90.8%, 95% CI 88.1-93.5). The RSL_ANN artificial neural network identified atrial fibrillation in ECGs acquired by portable devices with an AUC of 90.8% (95% CI 88.1-93.5%) in the testing dataset.