Key result
Guidewire-supported VOM ethanol ablation via bidirectional sheath achieves procedural success and arrhythmia freedom in 3 patients.
Why the study?
Physicians often encounter technical challenges during vein of Marshall cannulation, including coronary sinus sheath disengagement during manipulation, which complicates the procedure and reduces efficiency.
Does a 10-French bidirectional deflectable sheath with guidewire support improve procedural stability and success during Vein of Marshall ethanol ablation in patients with refractory atrial fibrillation and flutter?
Case Report (n=3)
Does a 10-French bidirectional deflectable sheath with guidewire support improve procedural stability and success during Vein of Marshall ethanol ablation in patients with refractory atrial fibrillation and flutter?
The use of a 10-French bidirectional deflectable sheath with guidewire support provides enhanced catheter stability and facilitates successful Vein of Marshall ethanol ablation in anatomically challenging cases.
Vein of Marshall (VOM) ethanol ablation is an effective adjunctive therapy for persistent atrial fibrillation and mitral-isthmus dependent atrial flutter; however, physicians often encounter technical challenges during VOM cannulation, including coronary sinus (CS) sheath disengagement during manipulation which may complicate the procedure and reduce efficiency. Our case series describes a simplified and stability focused technique that utilizes a 10 French bidirectional deflectable sheath (Medtronic Flexcath Contour) that is supported by a Terumo Glide Advantage wire to enhance CS stability. Our approach was used in three patients aged 62-74 years old, two of which were females and had persistent symptomatic atrial fibrillation and atrial flutter that were refractory to prior ablations and medical therapy. In these cases, anatomical challenges including prominent Eustachian ridges (inferred from initial cannulation difficulties and sheath instability during CS access) and variable VOM positions were identified via CS venography, contributing to cannulation difficulty. In all three cases, our technique allowed for stable CS access and successful VOM identification, facilitating cannulation, wire advancement, balloon placement, and ethanol infusion without any sheath disengagement. We used pre and post infusion voltage mapping which ultimately showed elimination of all potentials along the lateral mitral isthmus and ridge. There were no procedure complications, including those potentially associated with sheath advancement into the CS such as vessel trauma or perforation, and all patients were atrial arrhythmia free at 3- and 6-month follow-up. Our technique of using a larger-lumen deflectable bidirectional sheath with guidewire support provides enhanced catheter stability and may improve procedural efficiency, reduce cannulation time, contrast utilization, and fluoroscopy particularly in anatomically challenging cases.
No takes yet. Share an insight, caveat, or question.
Costa et al. (2026) conducted a case report in Persistent atrial fibrillation and atrial flutter (n=3). Vein of Marshall ethanol ablation using a 10 French bidirectional deflectable sheath supported by a Terumo Glide Advantage wire was evaluated on Procedural success (stable CS access, VOM identification, elimination of potentials) and freedom from atrial arrhythmia. Vein of Marshall ethanol ablation using a 10-French bidirectional sheath with guidewire support achieved successful cannulation, elimination of potentials, and arrhythmia freedom in all 3 patients.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: