Key result
CT-guided valve sizing in TAVI reduced the incidence of post-procedural aortic regurgitation ≥ grade 2 compared to TEE sizing.
Why the study?
Does CT-guided valve sizing reduce post-procedural aortic regurgitation in TAVI recipients compared to TEE-guided sizing?
Cohort (n=350)
Does CT-guided valve sizing reduce post-procedural aortic regurgitation in TAVI recipients compared to TEE-guided sizing?
CT-guided valve sizing for TAVI significantly reduces the incidence of post-procedural aortic regurgitation compared to TEE-guided sizing, likely due to larger valve implant sizes.
Answers are grounded in this paper and cite their sources.
May favor CT-guided TAVI sizing to lower moderate AR risk; hypothesis-generating pending randomized trials.
AIMS: Transoesophageal echocardiography (TEE) is considered the gold standard method for annulus measurement in transcatheter aortic valve implantation (TAVI). However, computed tomography (CT) has potential advantages compared to TEE. We sought to assess the impact of CT-guided valve sizing on post-procedural aortic regurgitation (AR). METHODS AND RESULTS: We compared procedural characteristics and clinical outcomes in patients undergoing either TEE-guided or CT-guided TAVI. Among 350 consecutive TAVI recipients, the mean age was 83.2 ± 6.4 years and the logistic EuroSCORE was 22.4 ± 11.2%. The mean Diam-TEE was similar in both groups (22.3 ± 1.9 mm vs. .0 ± 1.8 mm, p=0.092). The mean annulus diameter by CT (mDiam-CT) was larger than mean Diam-TEE (23.6 ± 2.0 mm vs. 22.3 ± 1.9 mm, p<0.001), and resulted in larger valve implant sizes compared to the TEE-guided group (25.8 ± 2.1 mm vs. 25.0 ± 1.9 mm, p<0.001). The incidence of post-procedural AR ≥ grade 2 was significantly reduced in the CT-guided group (15.4% vs. 24.0%, p=0.044), with a similar risk of annulus rupture (0.6% vs. 1.7%, p=0.31). The only predictor of post-procedural AR ≥ 2 was the "valve/mDiam-CT ratio" (HR 0.36 by increase of 0.1, 95% CI: 0.17-0.77, p=0.008) by multivariate analysis. CONCLUSION: CT-guided valve sizing in TAVI significantly reduces the incidence of post-procedural AR compared to TEE sizing. This strategy may have the potential to improve clinical outcomes.
No takes yet. Share an insight, caveat, or question.
Hayashida et al. (2012) conducted a cohort in Transcatheter aortic valve implantation (TAVI) (n=350). CT-guided valve sizing vs. TEE-guided valve sizing was evaluated on Post-procedural aortic regurgitation ≥ grade 2 (p=0.044). CT-guided valve sizing in TAVI reduced the incidence of post-procedural aortic regurgitation ≥ grade 2 compared to TEE sizing.
Synapse has enriched 10 related papers. Consider them for comparative context: